Recommendations For Using The Battery - Promax RP-200 Manual Del Usario

Generador multiportadora para banda 5-900 mhz
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

When the battery charging is completed, the light will change to green,
indicating that a maintenance charge is taking place.
2)
If the instrument is operating and the voltage adapter is connected, this serves
to power the equipment and to provide a battery maintenance charging; in this
situation the charge indicator remains in green.
ATTENTION
Whenever the equipment is power off or the external voltage adapter is
connected a battery charging process restarts.
It is for that reason recommendable to discharge the battery using instrument
without external power adapter to make complete the charge / discharge process.
ATTENTION
The charge system of RP-200 incorporates a security system that does not allow
the process charge from certain temperature limit, beginning the maintenance
charge instead, with indicator flashing in green/amber until the temperature downs
to the required value.

3.1.2.2 Recommendations for using the battery

In case of anticipating a long period of inactivity for the equipment it is
recommended to store it with the battery discharged.
When the equipment starts the operation after a long period of inactivity to follow
next steps:
Start the battery carrying process using the external voltage adapter until the
amber-coloured charge indicator will light up.
Use the equipment in normal way, reason why after one to three whole cycles of
charge/discharge, depending on the time and temperature of inactivity, the battery will
have been reconditioned.
Page 8
USER'S MANUAL. RP-200
08/2006
Tabla de contenido
loading

Tabla de contenido