Description of control panel
Control panel for 24V d.c. gear motors,
powered by 230V a.c. at 50-60 Hz (single-
phase).
Designed to control single FERNI, EMEGA,
FROG and ATI gear motors .
Designed and built entirely by CAME
CANCELLI AUTOMATICI S.p.A. to meet UNI
8612 safety standards at an IP 54 protection
level.
Housing in ABS is equipped with vents to
provide internal air circulation.
Guaranteed 12 months, unless tampered
with.
This control panel is powered by 230V a.c.
across terminals L1 and L2, and is protected
by a 3.15A fuse on the main power line.
Control systems are powered by low voltage
and protected by a 630mA fuse.
The total power consumption of 24V
accessories (which are protected by a 3.15A
fuse) must not exceed 40 W.
In addition to normal endstop slowing when
closing and opening, the control panel also
allows slowed-down initial opening and
closing movements. The ADT card (supplied
in the control panel box) manages these
slower movements, also decreasing the
amount of connection cables (see pages 20/
21).
Safety
Photocells can be connected to obtain:
- Re-opening during the closing cycle (2-
C1), if the photocells identify an obstacle
while the gate is closing, they will reverse
the direction of movement until the gate is
completely open;
-4-

GENERAL CHARACTERISTICS

- Partial stop, shutdown of moving gate, with
activation of an automatic closing cycle (2-
C3);
- Total stop (1-2), shutdown of gate movement
without automatic closing; a pushbutton or
radio remote control must be actuated to
resume movement).
- The electrical panel includes an
amperometric sensor for the motor which is
triggered whenever an obstacle blocks
movement during opening or closing. If
operating speed, the sensor inverts the
movement direction. If it is slowing down, the
motor stops. The sensor's sensitivity can be
adjusted using the trimmers.
- The transformers are equipped with a guard
that will keep the doors open in case of
thermal overload . They are closed again only
after the temperature falls below the
emergency threshold.
Accessories which can be connected to
this unit
- "Gate open" signal light (10-5);
-
remains on from the moment the doors begin
to open until they are fully closed (including
the automatic closing time).
closing is not activated, the lamp remains on
only during movement.
Connect it to terminals 10-E3 and select it
with a jumper. It is an alternative to the
second radio channel (see page 16);
- Movement flashing lamp with pre-flashing
option (dip 4 function selector);
- Electric lock ;
Cycle lamp to light the passage area: it