A
4WV
Terminal Strip
OF
Indoor Unit
COMP
L
N
Model
Voltage Range**
Power Supply Cable Size
Number Of Conductors*
Interconnection Cable Size
Number of Conductors*
Recommended Fuse*
IMPORTANT: * These values are for information only, they should be checked and selected to comply with the local
and/or national codes and regulations. They are also subjected to the type of installation and size of con-
ductors used.
** The appropriate voltage range should be checked with label data on the unit. ETL listed is only
applicable to 60Hz power supply only.
CE40DR / 50DR
A
4WV
OF
Terminal Strip
Indoor Unit
COMP
L
N
Ensure that the colors of wires on the outdoor unit and the terminal markings are the same as the indoor unit
respectively.
Outdoor Coil Sensor
Interconnection Cable
Power Supply Cable
380V – 415V /3Ph /50Hz + N +
mm
2
(50/60Hz)
2
mm
(50/60Hz)
A (50/60Hz)
Outdoor Coil Sensor
Interconnection Cable
Power Supply Cable
!
Caution
1-9
A
4WV
OF
COMP
Terminal Strip
Outdoor Unit
L
N
The electrical power must be provided with
L
!
protection devices (circuit breaker or fuse)
N
with double pole separation system (phase +
neutral) with minimum contact gap of 3mm.
40DR
!
or 208V – 230V /3Ph /60Hz + N +
1.5 /2.5
5
1.5 /1.5
7
10 /20
A
4WV
OF
Terminal Strip
Outdoor Unit
COMP
L
N
R
S
The electrical power must be provided
T
!
with protection devices (circuit breaker
N
or fuse) with pole separation system,
minimum contact gap of 3mm.
50DR
!
2.5 /4.0
5
1.5 /1.5
7
16 /25