2.
If the GFCI test correctly, restore
power by FIRMLY pushing the
"RESET" button back in until you
hear or feel a distinctive "click". IF
THE GFCI FAILS TO RESET PROP-
ERLY, DO NOT USE EITHER OUTLET
OF THE DUPLEX RECEPTACLE. Have
the unit serviced by an authorized
Customer Service Representative
immediately.
3.
High vibration or severe mechani-
cal shock loads may cause the GF-
CIs to trip. IF EITHER GFCI TRIPS BY
ITSELF AT ANY TIME, reset it and
perform test procedures 1 and 2.
4.
Repeat steps 1-3 for the second
GFCI.
ALTHOUGH THE ABOVE TEST PROCE-
DURES WILL INDICATE PROPER GFCI
OPERATION ON AN UNGROUNDED
OR IMPROPERLY GROUNDED GENER-
ATOR, THE GENERATOR MUST STILL
BE GROUNDED PER THE GROUND-
ING INSTRUCTIONS LISTED IN THIS
YEAR
JAN.
FEB.
NOTE: Situations exist where a GFCI will not afford any protection against the hazards of electrical shock.
Example: if a person touches two or more conductors from a damaged cord set and is not in direct contact with the ground,
he or she may receive a shock. Since there is no path to ground for a ground fault current to flow through, the GFCI will
not operate and serious injury may result.
The GFCI are merely an added safety feature. There are no substitutes for good safety precautions, correct electrical
practices and proper maintenance of cords, equipment and connections.
®
MANUAL FOR THE GFCI TO FUNC-
TION PROPERLY AND PROTECT THE
USER FROM ELECTRICAL FAULTS.
Cleaning And Gapping Spark Plug:
If the plug is contaminated with car-
bon, remove it using a plug cleaner or
wire brush.
Check the spark plug gap and reset it
if necessary. The spark plug gaps are
listed below. To change the gap, bend
the side-electrode only, using a spark
plug tool.
Spark Plug: NGK BPR6ES
Spark Plug Gap: 0.7-0.8 mm (0.03 in.)
Install and tighten the spark plug.
Torque - New: 8.7-10.9 ft-lb Torque -
Retighten: 16.6-19.5 ft-lb Connect the
spark plug lead.
Belt Tension Adjustment:
To maintain peak performance of your
unit, it may be necessary to adjust the
belt tension on occasion.
Follow the procedure outlined below.
MARCH APRIL MAY
JUNE
9
1.
Remove the beltguard and loosen
the two nuts on each side of the
pump or engine. There are a total
of 4 nuts. For loose alternator
belts, loosen the engine and pump
to adjust belts. If only the pump
belt is loose, only the pump will
need adjustment.
2.
Turn the cap screw clockwise until
a 1/2 inch belt deflection is noticed
between the pulleys.
3.
Tighten the side nuts.
4.
Put a straight edge across both
pulleys. If necessary, loosen one set
of pulley screws and adjust in or
out to properly align. Tighten the
pulley screws and check the ten-
sion again.
5.
Replace the beltguard and tighten
the fasteners securely.