Federal Signal AR2000-M Manual De Instalación Y Mantenimiento página 12

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

(CLASS 2) POWER OUT
TO AR2000-P
GND +24V
AR2000-M OR AR2000-P
AR2000-P
24VDC
FROM
AR2000-M
A. Connecting a Model AR2000-Z.
Using the provided 8 position modular cable,
connect the bottom communication port of the
AR2000-M to the top port of the AR2000-Z. (See section
3-7 part D for an explanation of the power connection to
this unit.)
B. Connecting a Model AR2000-P.
Using the provided 8-position modular
cable, connect the top communication port of the
AR2000-M to the bottom port of the AR2000-P. (Refer
to paragraph 3-7.D. for an explanation of the power
connection to this unit.)
3-11. TYPICAL CONNECTION EXAMPLES
A. Connecting a CD Player to the Audio Router.
Disconnect power from the AR2000-M.
(CLASS 2) POWER IN FROM
AR2000-M OR AR2000-Z
GND +24V
OUT TO AR2000-Z
AR2000-Z
SHIELD
TWISTED
PAIR
24VDC
300GC
FROM
AR2000-M
AM25CK
WARNING:
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. TO REDUCE
THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT REMOVE COVER OR EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
DRY CONTACT IN (N.O.)
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
PRESET 1
PRESET 2
PRESET 3
PRESET 4
PRESET 5
SHIELD
SHIELD
SHIELD
SHIELD
SHIELD
TWISTED
TWISTED
TWISTED
TWISTED
TWISTED
PAIR
PAIR
PAIR
PAIR
PAIR
NORMALLY
NORMALLY
NORMALLY
NORMALLY
NORMALLY
OPEN
OPEN
OPEN
OPEN
OPEN
CONTACTS
CONTACTS
CONTACTS
CONTACTS
CONTACTS
REMOTE
REMOTE
REMOTE
REMOTE
REMOTE
SWITCH
SWITCH
SWITCH
SWITCH
SWITCH
DEVICE
DEVICE
DEVICE
DEVICE
DEVICE
*
*
*
*
*
*
EXAMPLE OF REMOTE SWITCHES MAY INCLUDE SENSORS,
DOOR TRIGGER SWITCHES, PANEL SWITCHES, OR OTHER
WARNING:
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. TO REDUCE
THE RISK OF FIRE OR ELECTRICAL SHOCK, DO NOT REMOVE COVER OR EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES,
OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
AUDIO OUT
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
-
+
-
+
-
+
-
+
-
+
300GC
300GC
300GC
AM25CK
AM25CK
AM25CK
120VAC
120VAC
120VAC
120VAC
+24V
OPTO COMMON
CAUTION
CONTROL IN
BEFORE
FROM PRESET
INSTALLATION
DISCONNECT
POWER
PRESET 6
PRESET 7
PRESET 8
NOT USED
CONTROL OUT
WARNING
CONNECT CABLES
TO PROPER
JACK
SHIELD
SHIELD
SHIELD
TWISTED
TWISTED
TWISTED
PAIR
PAIR
PAIR
INSTALL JUMPER WIRE
18 GA, 3" TO 4" LONG
NORMALLY
NORMALLY
NORMALLY
OPEN
OPEN
OPEN
CONTACTS
CONTACTS
CONTACTS
REMOTE
REMOTE
REMOTE
SWITCH
SWITCH
SWITCH
DEVICE
DEVICE
DEVICE
*
*
*
TYPICAL REMOTE PRESET CONFIGURATION
Figure 3-4.
Decide which channel will get the CD player
connected to it. Using CH A as an example, set the
voltage selector for the Ch A input to the 1 Vrms position.
Connect the "+" input of CH A to the "+" output of the
CD player. Connect the "-" input of CH A to the "-" output
of the CD player. (See figure 3-7.) An input level adjust
exists just above the input selector switch for each input
channel. Adjust the input level as needed.
B. Connecting a 300VSC-1044-1 or 300MB to
the Audio Router.
Disconnect power from the AR2000-M. Connect
the output of either device to the CH B input in the same
manner as detailed for the CD player. Be sure to set the
input voltage selector to the appropriate voltage. (See
figure 3-7.)
AUDIO IN
CAUTION
BEFORE
INSTALLATION
ZONE 6
ZONE 7
ZONE 8
DISCONNECT
POWER
-
+
-
+
-
+
AUDIO OUT
WARNING
CONNECT CABLES
TO PROPER
JACK
SHIELD
TWISTED
PAIR
300GC
300GC
300GC
AM25CK
AM25CK
AM25CK
120VAC
120VAC
120VAC
Figure 3-5.
-11-
ABOVE
TO PRESET
BELOW
MODULAR CABLE
FROM AR2000-M
AR2000-P
CONTROL IN
FROM ZONE
ABOVE
CONTROL OUT
TO ZONE
BELOW
SHIELD TWISTED
PAIR FROM
MODULAR CABLE
AR2000-M AUDIO
FROM AR2000-M
300GC
TYPICAL ZONE CONFIGURATION
AM25CK
120VAC
290A4120-08B
AR2000-Z
290A4120-09B
Tabla de contenido
loading

Este manual también es adecuado para:

Ar2000-pAr2000-z

Tabla de contenido