The input power box houses a cage clamp strip
which furnishes supply output signals for the
chemical injection supply pumps.
An external power source must be used to
provide power to the injection system on the P
voltage. External liquid supply connections are
located on the rear of the machine.
To connect external supplies, use the following
procedure:
1. Facing the rear of the machine, locate the
1-1/2" opening found at the upper right-
hand side of the valve panel.
2. Gather external supply hoses and pull
through opening.
3. Locate the 4 capped nozzles on the rear of
the liquid supply dispenser and remove
caps. See Figure 11.
F232060
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
Nozzles:
5 1
2
3 & 4
Figure 11
4. Connect hoses to nozzles by pushing each
hose over nozzle lip. Hoses should fit
snugly onto nozzles and then be secured
with proper clamps.
1. Detergent
2. Bleach
3. Sour
4. Soft
5. Specialty
U149ME2A