Cleaning Instructions; Before First Use; Cleaning; Before Each Use - Lansinoh SIGNATURE PRO Instrucciones De Uso

Ocultar thumbs Ver también para SIGNATURE PRO:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Lansinoh
Signature Pro
®
Item
a. Signature Pro
Tubing
a1 Silicone Tubes 300 mm (2)
a2 Silicone Tube 600 mm
a3 Signature Pro
Tubing Y Connector
a4 Signature Pro
Tubing Strap
a5 Signature Pro
Pump Connnector
b. Breastmilk Expression Set Includes:
b1 ComfortFit
Breast Flange 25mm (2)
b2 Signature Pro
Breast Flange Body (2)
b3 Signature Pro
Diaphragm (2)
b4 Signature Pro
Diaphragm Cap (2)
b5 White Valve (2 + 2 extra)
b6 5 oz (150 ml) Bottle (2)
c. Storage Lids
d. Signature Pro
AC Adapter/power cord
B
C
A
Two extra white valves are included. Larger size flanges are sold separately.
To order replacement parts or larger size flanges
please visit www.lansinoh.com/store.
8
Breast Pump Parts
Item Number
#53403
#53405
#50417
#53453
#50408
#53454
#53402
#53410
#53401
#53451
#53450
#50409
B4
B3
A1
A3
A2
B2
B5
B6
D
A4
A5

3. CLEANING INSTRUCTIONS

Unless otherwise instructed by your healthcare provider,
follow these sanitizing and cleaning instructions.
3.1 Before First Use - Sanitization
1. Prior to using the set for the first time, disassemble and
boil all parts of the Breastmilk Expression Set that come
into contact with breastmilk for 10 minutes.
Ensure you use enough water to keep parts
afloat while boiling.
Do not boil the tubing and tubing connector. The Lansinoh
Pro
is a hygienic, closed system design, which ensures breastmilk will
not enter the tubing or motor.
2. Remove all parts from water immediately after boiling, using caution as parts will
be hot.
3. Completely air dry before assembly and use. Partially dried parts may affect
operation of the pump. Please ensure parts are completely dry before use.

3.2 Cleaning

Set aside the tubing and tubing connector.
The breast flange and bottles may be cleaned in the upper rack of your
dishwasher or hand washed with dish soap in hot water. For best results, we
recommend using a baby bottle brush to clean the bottle and a baby nipple
brush to clean the insides of the breast flange. DO NOT use solvents or
abrasives. Rinse with hot, clean water.
B1
All other parts of the Breastmilk Expression Set should be hand washed to
prevent loss and to extend their usefulness.
To clean your breast pump base, wipe with a damp cloth, using only water or
mild soap.

3.3 Before Each Use

Always wash hands thoroughly with soap and water before handling the
Breastmilk Expression Set, the pump body, or other attachments.
Ensure that the tubing is free of any liquid or moisture. Do not operate the pump
if liquid or moisture is visible in the tubing.
Ensure diaphragms are completely dry before use.
Before each use, visually inspect the individual components for cracks, chips,
tears, discoloration or deterioration, as this may affect the functionality of the
Breastmilk Expression Set. Please visit www.lansinoh.com/store or call
1-800-292-4794 for further guidance and replacement parts.
Do not boil or
wash tubing or
connector!
When sanitizing
parts, use enough
water to keep
parts afloat!
Signature
®
9
Tabla de contenido

Solución de problemas

loading

Tabla de contenido