Johnson Pump SPXFLOW Viking Universal Manual De Instrucciones página 11

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Never let sharp particles enter pump which can cut the diaphragm.
Preventing from accidental loss of bilge-pump handle, rope and snap-hook should
always be connected at any location of handle.
Capacity of this pump system is not intended to drain the craft in case of serious
damage at hull.
Winterization
To avoid damages from freezing, drain pump and all pipe work from water.
Never operate a frozen pump.
Maintenance
Regular inspection of pump is recommended. Check the function of the pump.
Regularly clear debris from pump inlet.
At a clogged pump, remove the hose connections and operate the pump until it is free from
impurities.
Rubber components should be replaced if worn or every three years.
Service kit no. 09-47545
For references, see fig. 6.
Service kit no 09-47546
For references, see fig. 6.
Changing diaphragm
For position reference see fig. 6.
Loosen and remove the clamping ring screws, (pos 22 + 23).
Remove clamping ring halves, (pos 13). Hoses may be left.
Loosen and remove nut and washer in center of membrane plates, (pos 17+18).
Remove lower membrane plate, (pos 3) and replace diaphragm, (pos 2).
Reassemble in reversed order. Assure correct position of diaphragm before you tighten
center nut, torque 1,5 – 2 Nm, (pos 18). Check that diaphragm is "seated " in cover and
body grooves, (pos 11+1).
Distance between clamping ring halves 7,5 – 9 mm. See fig. 5.
Replacing valves
For position reference see fig. 6.
Disconnect the Klick Tite connectors (pos 6, 8 or 24, 25) with hoses from the pump.
Replace the valves (pos 7 and 9) in the ports. Be careful that each valve gets its proper
position. Be sure that correct valve is installed with the correct port.
Flap valve (pos 9) is for inlet and tricuspid valve (pos 7) is for outlet.
The text of the inlet valve (flap valve) should be turned against the diaphragm.
Relocate the Klick Tite connectors.
Lock the connectors with the clips (pos 10).
Waste management / Recycling
Dispose of the product in accordance with existing regulations.
Where appropriate, dismantle and sort the product by its material fractions.
Original instructions
Diaphragm, inlet- and outlet valves 2 pcs O-rings for ports,
2 pcs split pins and 2 clips for ports.
Handle and clips for handle.
> English
11
Tabla de contenido
loading

Tabla de contenido