Use of the shower head
To remove the shower head from its support, push the ring nut down
(1) and turn it about 45° (2).
After use, put the shower head back in place, press the ring nut
and turn it about 45°.
i
I
(
)
17
Press the water supply outlet into place as shown,
and fasten it from behind with the headless screw that was pre-
i
viously removed
(
1
)
.
i
I
(
18
)
(1) After inserting the gasket, screw the flexible
hose1/2" F-F (included) into the indicated tap (2).
(3) Then screw the other end of the flexible hose into the cross
cylinder, as shown.
i
I
(
)
19
Follow the same procedure to install the other flex-
ible hose.
i
I
(
20
)
Align the covers using a level.
i
I
(
)
21
Then permanently attach, from under the tub edge,
the shower head support the ring nuts with the screws (
Installation of the drain column
and of the knobs
IMPORTANT: for the installations described below, the tub
must be away from the walls so that it is possible to work
on the back (especially on the left-hand version of mod.
180x90). Also, in order to install the siphon, the tub must be
lifted from the floor, placing inserts under the feet.
i
I
(
22-24a: 180x90; 24b: CORNER
drain (complete with column-command) and, using a socket
wrench, place the upper part at a 45° angle, as shown.
i
I
(
23
) (1) Disassemble the cover of the drain and after
placing
a bead of silicon on the groove of the drain body (2), ap-
ply the gasket as shown (3).
i
I
(
) From under the tub, install the drain body in the
24
hole in the bottom and, from above the tub, screw the ring
nut back into the drain body, as shown.
NOTE: the side fitting of the drain pipe
face the back of the tub.
i
I
(
24a, mod. 180x90) To correctly position the side fit-
ting of the drain (1a), the drain body must be installed in one
direction or in the other, depending on whether the tub is RH
or LH. IN any case it must be parallel to the wall that the short
side of the tub will be placed against (1b).
i
I
(
24b, mod. Corner) The body of the drain must be
positioned diagonally to the provided excavation, as shown
i
(also see
A1).
i
I
(
25
)
(1)
After installing the gaskets and the ring nut
on the siphon, fasten it to the body of the drain
ing a bead of silicon in between
(4) Fasten to the side fitting of the drain, using a clamp, the
mesh rubber hose from the distributor (located under the
back of the tub).
*
)
Take the body of the
(1a)
must always
(2-3), plac-
.
i
I
(
26
) Take the two plastic tubes shown in the figure. Af-
ter inserting the o-rings in the grooves
wo pieces of tube (B) and on the end indicated install the gas-
ket and the ring nut
Then install the manifold
(4)
Cut the tube (C) to size, then install on the indicated end the
gasket and the ring nut (5).
NOTE: to cut tube C to size, simulate its final installation
(under the tub edge, see
it can be shortened.
i
I
(
) (1-2) Then attach the tubes to the drain body, tight-
27
ening the ring nuts.
i
I
(
) Place the manifold under the tub edge, in the area of
28
the corner, and attach it to the threaded bar as indicated.
i
I
(
) Tighten the ring nut with nut on the column con-
29
trol, to about halfway. Then loosen the coupling with o-ring.
i
(
) From under the tub edge, insert the control in the
30
).
indicated, tightening the coupling from above.
i
I
(
31
) (1) Fasten the column control to the tub edge,
screwing the coupling all the way down and tightening tem-
porarily the nut below (2). Then apply the square cover (3).
i
I
(
) After checking alignment of all square covers,
32
tighten the nut permanently(
i
I
(
)
34
(1) Install the two pins on the shafts of the taps; (2)
turn them until the taps are in the "closed" position and fasten
them with hex screws (3).
i
I
(
35
) (1-2) Install the knobs on the pins, so that the hole
faces the inside of the tub; (3-4) check that the knobs are
parallel to the sides of the square covers and secure them.
Finally, press in the plastic plugs (blue for cold water and red
for hot water).
i
I
(
) (1) Raise the cover of the drain via the lever of
36
the column control; (2-3) install the remaining knob so that
the hole faces the outside of the tub, referring to the infor-
mation provided for the other knobs.
Levelling and fastening of the tub
i
I
(
37a: 180x90; 37b: CORNER
ner of installation (
pipes and tubes) and, after levelling it, adjust the height from
the floor as well, using the levelling feet (1). The upper level of
the tub, measured on the external edge, must be at a height of
60 cm from the floor. To compensate for possible irregularities
of the floor, the bath feet can be regulated from -0,5 + 1 cm (use
a long level on the top rim of the bath).
Do not use the frame locking nuts (A) (indicated by the
label with the red arrow).
Take care not to damage the siphon (which needs to
fit into the excavation in the floor) during movement
of the tub.
8
, assemble the t-
(1)
(2)
.
(3) as indicated.
i
28) and then check how much
i
).
33
) Place the tub in the cor-
raising it by the edge and NEVER by the