2.3
Main components stationary used
heater (vegetable oil or biodiesel
(fig. 3)
A
Cover
B
Flue connection
C
Combustion chamber
D
Connection for hot air fan
E
Identification plate
F
Fuel filter
G Switch box
H
Fuel tank
I
Fuel pump
J
Drain cock
K
Fill filter
L
Fuel pipe
M Return line
N
Inspection window
O Fuel supply pipe
P
Heat distributor with fan
Q Maximum thermostat
2.4
Main components of the burner
(fig. 4)
A
Explosion window
B
Combustion chamber
C
Vaporisation ring
D
Vaporisation section
E
Combustion air ventilator
F
Burner dish
G Overflow protection
H
Fan thermostat
I
Thermostat pump - and oxygen motor
J
Shovel
2.5
Switch box (fig. 5)
A.Switch control
-
0: The pump is switched off
-
1: Low pump speed
-
2: High pump speed
B
Control light Low pump speed
C
Control light High pump speed
D
Pump regulator
E
Connection cable
20
2.6
The Bio Energy has the following thermostats:
When the pumpthermostat is sufficiently pre-
•
heated, the fuel pump automatically starts up.
•
Maximum thermostat
The thermostat stops the fuel pump when
the combustion temperature gets too
high.
•
Fan thermostat
The thermostat starts up the hot air fan
as soon as the heater reaches the right
temperature. After switching off the
heater, the fan thermostat ensures that
the hot air fan keeps running, which cools
the heater. As soon as the heater has
cooled down, the fan thermostat switches
off the hot air fan.
2.7
•
3
3.1
1. Remove packaging from the heater.
2. Remove packaging from the loose parts
3.2
1. Ensure that the used heater (vegetable
2. Correctly attach the parts of the
3. Open the filling cover and fill the tank with
40.020.944 - rev. 05 - 2015
Thermostat
Accessories
Flue with rain cap
PREPARATIONS
Removing the packaging
in the combustion chamber.
Installation
oil or biodiesel) is positioned horizontally.
combustion chamber, see fig. 4.
fuel.
Caution
Only the following oil types may be
used in the stationary used
(vegetable oil or biodiesel) heaters:
•
Vegetable oil
•
Biodiesel
Bio Energy series