I N S T A L L A T I O N
Based on blower and ducting option selected,
go to the relevent section:
A - Installation using lexible blower
attached to downdraft
B - Installation using lexible or remote
blower - mounted in a remote location -
ducting through front panel opening
C - Installation using lexible or remote
blower - mounted in a remote location -
ducting through left, right or rear
A - Installation using lexible blower
attached to downdraft
(Purchase Model VTD600P Flexible Blower separately.)
1. Remove hex nuts to remove front panel cover.
2. Determine whether lex blower will discharge to the left, right,
or down.
3. If blower discharge is down, remove (4) #8-32 hex nuts and
electrical panel.
4. Place blower over studs around front panel opening.
5. Tighten hex nuts to secure blower in place.
BLOWER
SUPPORT LEGS
5. Remove bolts from lex blower housing. Attach blower support legs
to lex blower housing with these (4) bolts. Do not tighten bolts at
this time.
B - Installation using inline or remote
blowers - with ducting through front
panel opening
CAUTION
If lexible blower is mounted as an inline blower: Do not use legs
alone for support. It may be necessary to add extra support for
the lexible blower.
1. Remove hex nuts to remove front panel cover.
2. If blower discharge is down, remove (4) #8-32 hex nuts and
electrical panel.
3. Place 6", 8", or 10" (152mm, 203mm, or 254mm) round rough-in
plate (purchase separately) over studs around front panel opening.
4. Tighten hex nuts to secure remote discharge plate in place.
(4) BOLTS