Installation of Spout and Handle
1. Cut off the outer plaster guard
with a hack saw and ensure that the
interval between the raised edge of
the outer plaster guard and the wall
surface is within 2mm. (The edge
shall not sink in the wall surface)
NOTE
Do not hurt the inner
ƒ
plaster guard when cutting
to avoid damaging the
internal cartridge sleeve.
2. Installation of handle part:
a. Pull out the inner plaster guard (Note: the inner plaster guard does
not work anymore after mounting is finished).
b. Cap the cartridge sleeve with the escutcheon near the wall surface.
(Note: Apply a small amount of soap water on the O-Ring inside the
escutcheon for lubrication in order to facilitate mounting).
c. Mount the handle onto the cartridge and use the screw to fix it and
mount the cap at the position of the set screw hole.
Inner Plaster Guard
(to be pulled out)
INSTALLATION PROCEDURE
Handle
6
Protective Cap
(White)
Cap
Within
1/16"
(2mm)
Inner
Plaster
Guard
Cartridge
Escutcheon
Set Screw
Hex wrench
(2.5mm)