TL8100 PROGRAMMABLE THERMOSTAT

3. THERMOSTAT WIRING

1
2
3
TL8100
Fig. 3. Wiring diagram for a line voltage circulator.
ELECTRIC HEATER
1
L
N
2
3
TL8100
Fig. 4. Wiring diagram for a line voltage electric heater.
V4043
L
1
2
3
TL8100
Fig. 5. Wiring diagram for a line voltage valve (V4043 or
MOTOR
V4044 OR V8044
VALVE OPERATOR
Fig. 6. Wiring diagram for a line voltage 3-wire valve
(V4044 or equivalent); V8044 may be used with 24 VAC
69-2017EFS—01
N
L
120 VAC OR 240 VAC
2 AMP MAXIMUM INDUCTIVE LOAD
L
M29965
G
G
N 120/240 VAC
5 AMP MAXIMUM RESISTIVE LOAD
L
M29966
N
N
120/240 VAC
2 AMP MAXIMUM INDUCTIVE LOAD
L
M29967
similar).
TL8100
RED
1
BLUE
2
3
YELLOW
M29968
power.
Fig. 7. Wiring diagram for a 24 VAC 2-wire valve
Fig. 8. Wiring diagram for a 24 VAC V8043F.
L
N
L
Fig. 9. Wiring diagram for a White Rogers 1311 valve.
N
Fig. 10. Wiring diagram for a 24 VAC furnace or hydronic

Remote Input Wiring

The thermostat has an input for connecting a home
automation system or a remote control system. When a signal
is received at this input, the thermostat switches to Vacation
mode. When the signal is removed, the thermostat returns to
the original mode. See Fig. 11.
2
V8043A, E
TL8100
1
1
R
2
C
3
1
CONNECT BLACK WIRES ON V8043A AND
YELLOW WIRES ON V8043E.
(V8043A,E or equivalent).
V8043F
TH, TR TH TR
TL8100
1
R
2
C
3
2
4
5
R
C
6
1
3
1311
1
R
FURNACE OR
2
T, T ON PANEL
W
3
TL8100
zone panel.
L
N
M29977
L
N
M29978
1
2
3
TL8100
M29970
M29971
Tabla de contenido
loading

Tabla de contenido