System control Panel

The generator control board, located inside the generator,
under the roof, is shown below. Brief descriptions of the
controls used during installation are:
a
- Menu/Programming navigation Buttons — See
Menu section for details
B
- Mini USB Port — Authorized Dealer Service Use Only.
c
- Generator Operation Control Buttons —
•"aUTo" Normal operating position. Press and hold
button to put unit into Automatic mode. In Automatic
mode, if a utility power outage is sensed, the system
will start the generator. When utility power is restored,
auto lets the engine stabilize internal temperatures,
shuts off the generator, and waits for the next utility
outage.
•"oFF" Turns off running generator, prevents unit from
starting, and resets any detected service codes.
oFF must be pressed and held for more than 5 seconds in
order to reset service code memory.
a
B
c
D
e
F
More information may be found in Controls in the
operator's manual.
menu
ok
esc
off
manual
auto
•"ManUaL" Used to manually start the generator.
– 15 amp Fuse — Protects the home generator DC
control circuits. If the fuse has 'blown' (melted open)
or was removed, the engine cannot crank or start.
Replace the fuse using only an identical ATO 15A fuse.
One spare fuse is supplied with the unit.
- cover — This protective cover must be removed to
access the fuse and the USB port.
- Digital Display — Displays generator mode, menu
options, service codes, and service engine indicators