Replacement Of Burner Nozzles - Bartscher 2955041 Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
ENGLISH
Follow these instructions.
1. Close the gas valve.
2. Remove the gas control knob (A).
3. Loosen the screws (B) and remove the
control panel (C).
4. Take out the injector D and replace it for a
new one which is appropriate for the used
type of gas (see attachment). After the
setting seal the screw.
5. Finally, reattach the control panel (C) and
the gas control knob (A)..
After completing all calibration
and adjustment work, check the gas
installation for leakages and whether
the device operates properly.

Make sure that the flame is stable
GB
at
minimum
pressure
.
9.3.

Replacement of burner nozzles

Follow these instructions.
1. Close the gas valve.
2. Remove the gas control knob (A).
3. Loosen the screws (B) and remove the control
panel (C).
B
and
maximum
output
A
C

After adjustments, attach the prepared
sealing marks and/or seal calibration screws.
B
D
4. Remove the nozzle C and replace it with a
nozzle intended for the used gas (see table).
5. Finally, set the device to the initial status
D
14
A
C
ID 17