Tuthill Sotera 825P Manual De Funcionamiento Y Seguridad página 8

Medidores de salida de pulso digital
Ocultar thumbs Ver también para Sotera 825P:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Pulse Output Configuration
A) Press the ON and 4 buttons simultaneously for 3
seconds.
2
ON
Rate icon will display.
Current pulse options will be displayed (1,2,or 3) in the
large left most digit.
B) Press the ON button repeatedly until the desired pulse
output configuration number is displayed.
2
ON
C) Press button 2 to save and return to normal operating
mode.
2
ON
Pulse Configuration Options
Pulse width is 10 ms.
Option 1**
100:1
Gal**
100
Quart
25
Liters
26.42
Pint
Raw counts, equivalent to 117 - 125
Oz
Special
Internal pulse resolution per unit of measure (raw count).
**Option 1 and Gallons are the factory default.
Pulse Output Configuration and Flow Rate
3
4
3
4
3
4
Option 2
Option 3
10:1
Raw
10
2.5
2.64
counts per gallon.
Regardless of unit of measure selection, the meter will
generate a 4mA out at 0-1 GPM and scale linearly to
4-20mA from 1 - 25 GPM. At 25 GPM or higher, output
stays at 20mA.
See chart on page 15 for 4 - 20 mA specifications.
A) "When button 4 is held for 3 seconds, flow rate
is displayed. Fluid dispensed is still added to the
accumulated total and current total.
2
ON
"Rate" icon will be displayed.
Meter will continue to display flow rate until button 4 is
pushed again.
NOTE: 4-20 mA out and pulse output are always active
and not impacted by flow rate display.
8
Flow Rate
3
4
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Sotera 850p

Tabla de contenido