Holmatro DPU 31 PC Manual De Instrucciones página 40

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 93
EN
7.3
The connected tool does not work
/i
Possible cause
The tool is not connected properly.
The pressure relief valve on the pump is in the
"neutral" position.
7.4
It is not possible to connect a tool
/i
Possible cause
There is pressure in the hose or the tool.
The couplers are dirty.
7.5
It is not possible to disconnect a tool
/i
Possible cause
There is pressure on the hose from the tool.
7.6
Hydraulic oil leaks from the hydraulic oil filler cap
/i
Possible cause
There is too much hydraulic oil in the tank.
The oil is foaming.
7.7
The overheating LED is blinking
/i
Possible cause
The temperature of the pump is close to the
overheating point.
7.8
The tool works with jolts
/i
Possible cause
There is not enough hydraulic oil in the tank.
The oil is foaming.
40
Solution
Check the couplers. If necessary, clean the
couplers and connect them again.
Turn the pressure relief valve screw counter
clockwise as far as it can go ("operation" position).
Solution
Use the pressure relief tool to release the pressure
from the hose. Refer to section 5.8.
Clean the couplers.
Solution
Relieve the pressure. Refer to section 5.9.
Solution
Make sure the pump is in a horizontal position.
Drain hydraulic oil until the level is at the
maximum level indication on the dipstick.
Stop the pump. Start the pump again after a few
minutes.
Solution
Turn the deadman's handle of the tool to the
neutral position. If possible, open and close the
tool one time.
Solution
Make sure the pump is in a horizontal position.
Add hydraulic oil until the level is at the
maximum level indication on the dipstick.
Do not add hydraulic oil after changing tools
that have the plunger extended.
Stop the pump. Start the pump again after a few
minutes.
916.000.116_004
DPU 31 PC
Tabla de contenido
loading