DNCE−...−LAS
12
Technical specifications
DNCE−...−LAS
1)
Rated stroke
Mode of operation
Type of motor
Displacement encoder
Mounting position
End position protection
Temperature monitoring
Stroke reserve (both sides)
Retracting
Advancing
Max. work load when max. stroke is used
horizontal operation
Horizontal operation with ext. guide
Vertical operation
4)
Peak feed force
Continuous feed force
3)
Repetition accuracy
Max. velocity
1)
Theoretical total stroke = rated stroke + stroke reserve
2)
At 23 °C ambient temperature
3)
Note temperature influence
4)
Peaks and permanent forces without consideration of friction è chapter 13 Characteristic curves"
40
32
100
[mm]
Electrically linear direct drive
Linear AC servo motor
Relative measuring, magnetic, incremental, contactless
As desired
Integrated buffer for very slight cushioning energy
(only minimum protection)
Shuts down if motor overheats
1)
[mm]
3.3
[mm]
5.9
[kg]
1.5
2.8
3
[N]
93.7
2) 4)
[N]
33.7
[mm]
±0.02 mm
(for R = −2s, +2s; only with front fastening)
[m/s]
2
40
200
320
100
3.1
3.7
1
0.5
2.5
6
4
3.4
3
2
3
141
141
183
29.4
33.8
55.3
3
2
200
320
400
2.5
1.5
1.4
6
6
6
3
3
3
202
202
202
33.8
42.1
47.9
3
Festo DNCE−...−LAS 1003b English