2.3.8.3. Battery charger
2.3.8.3.1. Specifications
Marque: GenPARTS
Type: ACP2
Nominal input voltage: 230Vac - 50Hz/60Hz
Voltage range: 187Vac - 305Vac
Output: 13.2V dc; 2.5A
Environment:
o Ambient operating temperature: - 20 to + 60°C
o Storage temperature: - 20 to + 70°C
o Relative humidity: 95% at 20°C ("all climates")
Static regulation: 1% cumulative variations
o in input voltage
o in output current
o in ambient temperature
Noise and ripple: < 1% peak-to-peak
Breakdown voltage: - 2500V ac between input and output
- 2000V ac between earth and input/output
Conformity:
o Low Voltage Directive (DBT) no. 73/23/CEE modified by directive no. 93/68/CEE
o EMC Directive No. 89/336/CEE modified by directive No. 93/68/CEE
o EMC Standards: NF EN 55011; NF EN 61000-4-2; NF EN 61000-4-3; NF EN 61000-4-4; NF EN 61000-4-5; NF EN 61000-4-6.
Preheating circuit specifications: 250Vac - 50Hz/60Hz - 10A/AC1 max.
Consumption: 60VA: charger only; 1560VA: charger + preheating
FS: internal mains fuse type 5 x 20 rating 1A – T
F2: internal output fuse type 5 x 20 rating 5A – T
Weight: 0.5 kg
Output: ≈ 0.8
C16: wiring for charger supply/preheating
C100: preheating output connector
C 27: connector for battery output and preheating remote control.
2.3.8.3.2. Operation
A battery charger is factory fitted. The direct current (DC) leads for this battery charger are connected in the factory. The purpose of
the battery charger is to keep the starter battery at its maximum charge. The standard power packs/chargers for the ACP model are
voltage- and current-regulated.
The power packs/chargers for the ACP model are fully automatic and are voltage-regulated and have a current limiter (nominal
rating). The preheating function is activated using external terminals.