Metcal MX-DS1 Guia Del Usuario página 7

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

9.
Check the functioning of the slide latch and hinge by operating the latch,
opening and closing the upper body a few times. The parting lines (gaps)
between the rear of the chamber and the top rear of the right handle should be
parallel.
MAINTENANCE: REPLACING CARTRIDGE SEALS
1.
Turn off the system and remove the desolder cartridge.
2.
Pry out the cartridge seal (at the front end of tool) by gently prying it out with a
small screwdriver, paper clip, or other blunt instrument.
3.
Replace the cartridge seal by pushing it in.
MAINTENANCE: REPLACING CHAMBER SEALS
1.
Remove the air line and power cord from the desoldering handle.
2.
Open the desoldering handle and lay it down with the hinge side facing up
toward you
3.
Before removing the hinge pins, cover the hinge area with your hand as you
remove the top. They are spring loaded and might shoot out of the tool as the
top is removed. Take the end of a paper clip and push it into the small hole at
the front or rear of the hinge. This will push the hinge pin into the tool. You can
then wiggle the top of the tool away from the hinge pin. Repeat this with the
other hinge.
4.
Remove the top half of the tool.
5.
Remove the solder chamber seal using a knife.
6.
To install the new chamber seal, start with a short side, and use a screwdriver
or other blunt tip to tuck the seal lip into the retaining grove
7.
Next, tuck the other short side.
8.
Finish with the long sides.
TROUBLESHOOTING GUIDE: DESOLDERING TOOL DOES Not REMOVE SOLDER
1.
Check if the tip is heating up by applying solder to the tip. If it does not heat,
follow the steps under "Tip Will Not Heat" earlier in this manual.
2.
Turn the power supply off.
3.
Open the handle.
4.
Replace the Chamber filter if it appears dirty and full of flux.
5.
Replace the Chamber liner if it is full.
6.
Lay the edge of your hand over the top of the collection chamber to provide a
seal. Press the trigger of the tool and verify that you feel a strong suction
against your hand.
7.
If the suction is not strong, proceed to step 12. If the suction is strong and you
replaced wither the chamber filter or liner, close the tool, insert a cartridge, turn
the system on and press the trigger while melting some solder with the tip.
8.
If the solder is not sucked into the tool, clean the tip with a thin wire or Tip
Cleaner.
9.
If this does not help, turn the system off, remove the cartridge, and visually
- 6 -