INSERTING/REPLACING TIP CARTRIDGES INTO THE DESOLDER HAND-PIECE
1.
Make sure the system is
turned off.
2.
Pull out the cartridge
using the Cartridge
Removal Pad
3.
Insert the tip cartridge
into the desoldering
hand-piece by pushing
in the "back end" of the
cartridge (the end without the tip) as far as it will go. Notice that the tailpipe
must be oriented down.
4.
Turn on the system. The new cartridge should heat up to temperature quickly.
MAINTENANCE: CLEANING THE COLLECTION CHAMBER
WARNING: ALTHOUGH THE DESOLDER TOOL CAN BE OPENED AND CLEANED
WHILE THE SYSTEM IS ON, THE CARTRIDGE WILL BE HOT. USE EXTREME
CAUTION WHEN OPENING THE TOOL SO AS TO AVOID BURNING YOUR
FINGERS OR HAND ON THE EXPOSED CARTRIDGE
1.
Open the Desoldering Handle and
remove the Chamber Liner. The
liner has a convenient lift-out tab
to facilitate removal.
2.
In addition to replacing the
Chamber Liner when full, you
should periodically scrape any
solder or resin from the inside of
the upper half of the handle in the
area around the Cartridge tailpipe.
3.
Apply a layer of silicone grease to
the surface after it is scraped
clean. Check that the chamber seal surface is clean before closing the handle.
4.
Two cleaning brushes are included with your system. Use these with Isopropyl
Alcohol or detergent to clean flux and solder residue from the chamber and
cartridge seals.
NOTE: SILICONE GREASE WILL CONTAMINATE ELECTRONIC CONNECTIONS
AND SHOULD BE USED WITH CARE AROUND ELECTRONIC PARTS.
The Venturi Filter will collect resins and will need to be replaced as often as use dictates.
After time, the passageways below the filter will also clog with resin. When this happens,
follow the procedure below.
1.
Open the Desoldering Handle
and remove the chamber filter.
2.
Squirt flux cleaner in the
passage, and then pull the
trigger to suck the solvent
through the Venturi. Repeat until
Venturi is clear.
- 4 -