Waste water connection

Provide for an odor trap on the drain connection. The
connection on the odor trap must always be accessible
(not directly behind the appliance).
Important notes on the drain hose
Do not fit the drain hose at any point higher than
the bottom edge of the appliance
Drain: at least ø1.6" (40 mm) inner diameter
Drain connection: at least 4" (100 mm) lower than
the appliance drain
Do not kink the drain hose
Do not shorten the included drain hose
Drain hose: no more than 5.5 yards (5 m) long
Remove the transport lock from the drain hose
(metal clip) on the rear of the appliance

Install Appliance

Note: The appliance is heavy. It is advisable to install it
with a second person.
NOTICE: Before installing the appliance, be sure to
verify the cabinet dimensions and electrical
connections.

Mount to Cabinet

Use the included retaining plate and two screws to
fasten on the side bottom of the hinge side in the
installation cabinet. Mark the screw midpoint, the
retaining plate must be positioned precisely. Depending
on the installation situation, on partition floor or heating
drawer WS4.., turn the retaining plate by 180°. When
pushed into the cupboard, the appliance snaps into the
retaining plate.
Secure the appliance against tilting in the cupboard if
there is not intermediate shelf above the appliance:
fasten two commercially available brackets on both
sides inside the cupboard (at 17
3
/
" (5 mm) above appliance height).
16
90°
90°
3
/
" (450 mm) deep,
4