Electrical Grounding Instructions; Electrical Requirements - Viking Range Combi Steam/Convect VCSO210 Manual De Uso Y Cuidado

Ocultar thumbs Ver también para Combi Steam/Convect VCSO210:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

IMPORTANT–
Refer to Illustration 1 for proper location when building in above an
electric wall oven, a warming drawer or Drawer Microwave. Care-
fully follow both the electric wall oven/warming drawer/microwave
drawer installation instructions and Built-in Kit instructions. Be sure
that the clearance of the floor between the Combi Steam/Con-
vect™ Oven and the electric wall oven/warming drawer/microwave
drawer is a minimum of 2 inches (5.1 cm).
ELECTRICAL GROUNDING
INSTRUCTIONS
This appliance must be grounded. This oven is equipped with
a cord having a grounding wire with a grounding plug. It must
be plugged into a wall receptacle that is properly installed and
grounded in accordance with the National Electrical Code and
local codes and ordinances. In the event of an electrical short
circuit, grounding reduces the risk of electric shock by providing
an escape wire for the electric current.
Improper use of the grounding plug can result in a risk of electric
shock.

ELECTRICAL REQUIREMENTS

The electrical requirements are a 120 volt 60 Hz, AC only, 15 amp.
or more protected electrical supply. It is recommended that a
separate circuit serving only this oven be provided.
The oven is equipped with a 3-prong grounding plug. It must
be plugged into a wall receptacle that is properly installed and
grounded. Should you only have a 2-prong outlet, have a qualified
electrician install a correct wall receptacle.
A 3-prong adapter may be purchased and used temporarily if local
codes allow. Follow package directions.
A short power-supply cord is provided to reduce risk of becoming
entangled in or tripping over a longer cord.
Please Read and Follow
WARNING
9