Devices in the BGSM-100 and BGSM-120 series are GSM communicators which, in the absence of a PSTN line, transmit
vocal and digital alarms to System III or System II receivers, via GPRS. There are three models available for each series:
— The BGSM-100KCA and BGSM-120KCA kits including GSM/GPRS communicator electronic card and antenna with 25 cm cable;
— The BGSM-100KEA and BGSM-120KEA kits including GSM/GPRS communicator electronic card, antenna with 2 mt
cable and metal bracket;
— The BGSM-100BA and BGSM-120BA, including GSM/GPRS communicator electronic card, antenna with 25 cm cable and casing.
All information relating to a specific model shall be attested to by reference to the the corresponding code. The word
―Communicator‖ is being used to describe functions which are common to the various models. This manual provides
programming and operation of the GSM/GPRS alarm Communicator. If there are any special installation requirements, the
remote ANT-EU outdoor antenna and the magnetic BGSM-100CA or antenna with 25 cm cable may be used.
This Communicator is fixed and shall be installed by Service Persons only (service person is defined as a
person having the appropriate technical training and experience necessary to be aware of hazards to which that
person may be exposed in performing a task and of measures to minimize the risks to that person or other
persons). It shall be installed and used within an environment that provides the pollution degree max 2, over
voltages category II, in non-hazardous, indoor locations only. This manual shall be used with the Installation
Manual of the alarm control panel. All instructions specified within that manual must be observed.
Features
Simulates land line
Switches automatically to GSM Network in the event of
land line trouble (line down)
Manages and signals Incoming/Outgoing calls
GSM signal indicator
3 programmable terminals as Open Collector Outputs or
Input Lines (BGSM-120 series only)
Land line overvoltage protection
GSM Quad-Band
Antenna with magnetic base
SMS dialer (BGSM-120 series only)
Voice dialer (BGSM-120 series only)
Supports Contact ID communication format from a connected
control panel for communication over the GPRS network
GPRS/Internet communication with receivers Sur-Gard
System III / II
Technical Specifications
The input voltage to this can be drawn from the Control Panel or provided by the ADP1512 power supply (not supplied).
Models
Input Voltage
Standby current
Maximum alarm (Transmitting) current
Outputs
Operating frequency
Maximum loop resistance of line between
the device connected in series on LI
Maximum number of parallel devices
connected on LI
Operating Temperature
Dimensions (WxHxD)
Weight
BGSM-100/120
INTRODUCTION
PC-programmable options
11 SMS messages, each with a maximum length of
100 characters (2 for each Input Line plus 4 for Status
8 telephone numbers (max. 16 digits) programmable
for the SMS dialer (BGSM-120 series only)
4 phone numbers programmable for Contact ID Dialer
on GPRS
Up to 100 telephone numbers (max.16 digits) pro-
grammable for the remote activation of the OC output
Remote activation of the outputs through caller identi-
fication and/or SMS transmission (SMS transmission
for the BGSM-120 series only)
Credit balance check for pre-paid SIM CARDS (BGSM-
120 series only)
(PTM) monitoring of communication with the control unit
BGSM-100KCA, BGSM-100KEA,
BGSM-120KCA, BGSM-120KEA
between 10 and 27.6 V_
100 mA maximum (not including the outputs) at 13.8 Vdc
250 mA average (not including the outputs) at 13.8 Vdc
3 open collector, 100 mA
900/1800 MHz or 850/1900 MHz
5 to 40 °C / 41 to 104 °F
60.5x142x15.3 mm
(PCB only)
66 g
Indications and 1 Periodic), BGSM-120 series only
1 Kohm
1
90x190x75 mm
(without antenna)
BGSM-100BA,
BGSM-120BA
348 g
5
G