BGSM-120
The Open Collector outputs can be set as Bistable (activation and deactivation takes place by means of 2 separate
commands) or Monostable (the output remains active for the ON time and returns to standby mode when this period
has elapsed or when it is deactivated by means the specific SMS). Moreover, every output can be programmed to
provide a confirmation signal (an SMS programmed previously if output activation/deactivation is performed via SMS,
or a confirmation ring if output activation/deactivation is performed via caller identification).
 For further information on the terms ―Control string‖ and ―User code‖ used in the following sections,
please refer to the ―I/O‖ and ―Options->Codes‖ sections of the ―PROGRAMMING VIA PC‖ chapter.

Bistable outputs (BGSM-120 only)

Open collector outputs set as bistable can be activated in 2 ways:
1. By sending an SMS consisting of the User code between two # characters, the Control string (Control String can not
have initial blank spaces) and the characters ―=ON#‖, as follows:
2. Through caller identification: in this case the output is activated at ―cost-free‖ as the Communicator, after identifying the
caller, rejects the call and activates the output.
 A bistable OC output can ONLY be deactivated by sending an SMS message consisting of the User code
between two # characters, the Control string and the characters "=OFF#", as follows:
#User code#String=OFF#
 The default User code is ‗0001'; if you wish to change it, please refer to the section ―Remote programming by SMS
message->Changing the User code‖.

Monostable Outputs

OC outputs set as Monostable may be activated in 2 ways, through Caller Identification and via SMS (BGSM-120 only).

SMS (BGSM-120 only)

Send an SMS consisting of the User code between the # characters, the Control string (Control String can not have
initial blank spaces) and the characters ―=ON#‖,―=ON#TonU#‖ or ―=OFF#‖,as follows:
The ―=ON#tonU#‖ option is parameter allows to set the ON Time from 1 to 86400 seconds, with 1 second steps. The ON
Time can be set by means of the Communicator's Console software. ―Ton‖ is the required value and ―U‖ is the unit in hours
(H), minutes (M) and seconds (S), as shown in the following example:
#9876#HOUSELIGHT=ON#
#9876#HOUSELIGHT=ON#3600S#
#9876#HOUSELIGHT=ON#50M#
#9876#HOUSELIGHT=ON#3600#
 Remove the ―TonU‖ parameter, leaving the ―##‖ characters, to activate the output by SMS as programmed.
BGSM-100/120
#User code#String=ON#
#User code#String=ON#
#User code#String=ON#TonU#
#User code#String=OFF#
SMS
(example: #9876#HOUSELIGHT=ON# #)
(example: #9876#HOUSELIGHT=ON#)
(example: #9876#HOUSELIGHT=OFF#)
Output operating mode
Bistable Activation
Active for 3600 seconds
Active for 50 minutes
Active as per software programming,
the set ON time does not apply
G
15

Hide quick links:

Tabla de contenido