Pay As You Go Balance (BGSM-120 series only)

If the BGSM-120/BGSM-100 Console software has been used to program the device (see Options->Pay As You Go), it will
be possible to check how much credit is left on the pre-paid SIM CARD. If the credit balance check feature is enabled, an SMS
providing credit balance information (supplied by the operator) is sent to the first number in the phonebook at regular
intervals. For all operators which support credit balance requests via a network command, it will be possible to enter a
request for information using the BGSM-120/BGSM-100 Console software.
 PLEASE NOTE - The pre-paid SIM CARD credit management service may be suspended at any time, at the
discretion of each individual GSM network operator.

(PTM) monitoring of communication with the control unit

The constant monitoring of communication with the control unit (PTM function) allows the Communicator to transmit calls via
the GSM network if communication between the alarm control unit and the surveillance control unit does not take place
successfully over the PSTN telephone line. If programmed (using the BGSM-120/BGSM-100 Console software PTM page),
this feature only works when the PSTN line is connected to the LE terminals.
The PTM function correlates to the following Communicator alarm transmission modes:
1. Alarm on GPRS (IP communication - receiver).
2. Alarm on GSM (voice mode).
 The PSTN Fault event occurs when the PTM function activates.
The BGSM-100 series has the Open-Collector Outputs (the T1, T2 and T3 terminals). The BGSM-120 series has 3 terminals (the
T1, T2 and T3 terminals) that can be programmable as Inputs or/and Output: this terminals are programmed as Outputs by
default. The Open-Collector Outputs can be activated automatically (when certain pre-programmed events occur) or remotely,
through SMS trasmission (for the BGSM-120 series only) or caller identification from a number programmed previously.

Activating/Deactivating Automatic Outputs

The T1,T2 and T3 Open Collector outputs can be activated automatically by the following events:
 Land line trouble (line down), (T1, BGSM-100 series).
 GSM Network trouble (Limited/No Service), (T2, BGSM-100 series).
 Supervision message missing (BGSM-120 series only).
 Internal event communication failed (FTC), (BGSM-120 series only).
 Once an OC output has been automatically activated, it will only return to standby mode when all the causes
of activation have been cleared, except if there is a Failure To Communicate an internal event (FTC), in which
case it returns to standby mode after the ON Time has expired.

Remote Activation and Deactivation of the Outputs

 CAUTION - The GSM connection must be established before the outputs can be activated/deactivated remotely.
We recommend the device is programmed with the Black list enabled (Options->Dial Options) and White list
disabled (Phonebook->White list) for the numbers you wish to use for this function.
The number used to activate the outputs via Caller Identification must be visible.

BGSM-100

The T1 and T2 Open Collector outputs as BISTABLE, while the T3 output is MONOSTABLE (Once a Monostable output
has been activated, it will not deactive until On Time expires).