12. Standard Delivery
1
Twister evolution pro vacuum mixing unit
1
500 ml bowl, incl. paddle
1
Operating instructions
1
Spare parts list
1
Drilling template
1
Fastening set
13. Delivery Versions
No. 1825-0000 Twister evolution pro 230V / 50-60Hz,
incl. 500 ml-bowl with paddle
No. 1825-1000 Twister evolution pro 120V / 50-60Hz,
incl. 500 ml-bowl with paddle
14. Accessories
No. 1821-0101 Stand for benchtop units,
WxHxD: 230 x 680 x 290 mm
[9.062 x 26.772 x 11.426 inches]
No. 1821-0200 Premix spatula
15. Error List
Error
ON/OFF switch fails to
work.
Motor fails to start.
No or insuffi cient vacu-
um build-up.
("Err" shown on the dis-
play + audible signal)
Vacuum reduction/ven-
ting too slow.
Vacuum pump conti-
nuously on.
Paddle fails to turn.
Possible cause
•
Unit not connected to the power
outlet.
•
Unit fuse blown.
•
Faulty/damaged power cord.
•
Motor fuse blown.
•
Motor defective/damaged.
•
Inlet fi lter blocked.
•
Seal surfaces dirty.
•
Vacuum pump defective/dam-
aged.
•
Vent valve defective/damaged.
•
Inlet fi lter blocked.
•
Bowl detection pin jamming.
•
Motor fuse blown due to paddle
overload.
No. 1820-6500 Bowl, incl. paddle, 65 ml
No. 1820-6510 Paddle, 65 ml
No. 1820-6520 Bowl, 65 ml
No. 1820-0200 Bowl, incl. paddle, 200 ml
No. 1820-0210 Paddle, 200 ml
No. 1820-0220 Bowl, 200 ml
No. 1820-0500 Bowl, incl. paddle, 500 ml
No. 1820-0510 Paddle, 500 ml
No. 1820-0520 Bowl, 500 ml
No. 1820-0700 Bowl, incl. paddle, 700 ml
No. 1820-0710 Paddle, 700 ml
No. 1820-0720 Bowl, 700 ml
No. 1820-1001 Bowl, incl. paddle, 1000 ml
No. 1820-1010 Paddle, 1000 ml
No. 1820-1020 Bowl, 1000 ml
Corrective action
•
Check the power supply.
•
Replace the fuse (refer to Sec. 8.3).
•
Have the unit repaired.
•
Replace the fuse (refer to Sec. 8.3).
•
Have the unit repaired.
•
Clean the fi lter (refer to Sec. 8.1).
•
Clean the seal surfaces (refer to Sec. 8.2).
•
Have the unit repaired.
•
Have the unit repaired.
•
Clean the fi lter (refer to Sec. 8.1).
•
Have the unit repaired.
•
Clean the paddle and bowl.
•
Replace the fuse (refer to Sec. 8.3).
Subject to modifi cations.