5.3.10 Defender Visor; 5.3.11 Edge Trim; 5.3.12 Reflective Trim; Breakaway Tabs (Models 660C, 664, 880, And Hp3) - MSA Cairns Serie Manual De Uso

Para bomberos
Ocultar thumbs Ver también para Cairns Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5.3.10 Defender Visor

If any of the following conditions exist, replace the visor or attachment clips, as applicable:
Blistered, bubbled, cracked, or charred lens
Broken quick-connect attachment clips
Lens will not stay in the stowed position and/or cannot be adjusted

5.3.11 Edge Trim

If any of the following conditions exist, replace the edge trim:
Broken or exposed aluminum core
Exposed reinforcing wire on rubber edge trim
Edge trim pulled away from back brim D-ring holder
NOTICE
If the edge trim is separated from the brim but still intact, the edge trim can be re-attached.

5.3.12 Reflective Trim

CAUTION!
For Models HP3, 360R, and 360R-13, reflective trim must completely cover any exposed rivets on the
sides of the fire helmet. Otherwise, NFPA compliance may be compromised.
If the reflective trim is charred, partially detached, nonreflective, and/or missing, replace it.

5.3.13 Breakaway Tabs (Models 660C, 664, 880, and HP3)

If the breakaway tabs are missing, bent, or have damage, replace them.
5.4

Advanced Inspection

WARNING!
Only a manufacturer-trained organization, verified organization, or verified Independent Service
Provider (ISP) can perform advanced inspection.
Advanced inspection includes all of the items listed for routine inspection and all of the following items.
After the fire helmet is put into service, do an advanced inspection of all protective ensemble elements
at least every 12 months, or whenever a routine inspection removes the ensemble from service, which-
ever occurs first.
NOTICE
For the purposes of replacement (according to
the fire helmet ensemble is based on the oldest original part shipped as a component of the complete
compliant fire helmet ensemble, irrespective of the manufacturing date of the replaced parts.
Do the following applicable procedure, according to the model type, to disassemble the fire helment
and inspect all components for the conditions listed in Section 4.3, Routine Inspection.
NFPA
1851) and warranty, the manufacturing date for
MSA Cairns Fire Helmets
US
17
Tabla de contenido
loading

Tabla de contenido