Addi onal Clearances (Indoor Models)
Check on whether local codes supersede these clearances.
•
Avoid termina on loca ons near a dryer vent.
•
Avoid termina on loca ons near commercial
cooking exhaust.
•
You must install a vent termina on at least 12
inches from the ground
Important considera ons for loca ng vent
termina on under a soffit (ven lated or unven lated)
or eave vent; or to a deck or porch
•
Do not install vent termina on under a soffit vent
such that exhaust can enter the soffit vent.
•
Install vent termina on such that exhaust and
rising moisture will not collect under
eaves. Discolora on to the exterior of the
building could occur if installed too close.
•
Do not install the vent termina on too close
under the soffit where it could present
recircula on of exhaust gases back into the
combus on air intake part of the termina on.
(0.30 m ) to
an inside
corner
8
36"
12"
V
V
12"
(0.30 m) between
terminals at same
level
INSIDE
CORNER
Jacuzzi Signature Water Heaters J‐S180/J‐S199
(1.52 m)
between
terminals at
different levels
V
V
60"
V
(0.61 m) to wall or parapet
24"
V
12"
(0.30 m) between
terminals at same
V
V
level
60"
V
(1.52 m) ver cally
between terminals