Connect Water Heater to Water Supply 
Water connec ons to the tankless water heater 
should follow all state and local plumbing codes. 
If this is a standard installa on, refer to the Piping 
Diagram for Basic Installa on. 
1.  Plumb water supply to the tankless water heater 
on the 3/4" MNPT connec on at the bo om of 
the unit marked "Water Inlet", which is the cold 
water supply. 
2.  Plumb the building hot water supply to the 3/4" 
MNPT connec on marked "Water Outlet", which 
is the hot water supply.   
If a pipe cover will be installed, make sure water lines 
to the water heater fit.  
Checklist for Plumbing 
□ 
Purge the water line of all debris and air by 
closing the hot isola on valve and opening the 
cold isola on valve and its drain.  Debris will 
damage the water heater.  Use a bucket or hose 
if necessary. 
□ 
Ensure that hot and cold water lines are not 
crossed to the unit and are leak free. 
□ 
Ensure that a pressure relief valve is installed with 
a ra ng that exceeds the BTU input of the water 
heater model.  Refer to the ra ng plate on the 
side of the water heater for BTU input. 
□ 
Clean the inlet water filter by closing the cold and 
hot water inlet isola on (shut‐off) valves.  (Turn 
off the water supply if a shut‐off valve is not 
installed.)  Put a bucket under the filter at the 
bo om of the water heater to catch any water 
that is contained inside the unit.  Unscrew the 
water filter.  Rinse the filter to remove any debris.  
Install the filter and open the isola on valves. 
18 
Jacuzzi Signature Water Heaters J‐S180/J‐S199 
Installa on of Gas Supply 
WARNING
1.  If you are not knowledgeable or qualified to 
install gas lines or connec ons, then contact  a 
licensed professional to install the gas supply. 
2.  Turn off 120v power supply. 
3.  Turn off the gas. 
4.  Gas is flammable.  Do not smoke or provide other 
igni on sources while working with gas. 
5.  Do not turn on the water heater or gas un l all 
fumes are gone. 
General Instruc ons 
MUST DO 
A manual gas control valve must be placed in the 
gas supply line to the water heater.  A union can be 
used on the connec on above the shut off valve 
for the future servicing or disconnec on of the 
unit. 
Check the type of gas and the gas inlet pressure 
before connec ng the water heater.  If the water 
heater is not of the gas type that the building is 
supplied with, DO NOT connect the water heater.  
Contact the dealer for the proper unit to match the 
gas type. 
Check the gas supply pressure immediately 
upstream at a loca on provided by the gas 
company.  Supplied gas pressure must be within 
the limits shown in the Specifica ons sec on with 
all gas appliances opera ng. 
Before placing the appliance in opera on all joints 
including the heater must be checked for gas 
ghtness by means of leak detector solu on, soap 
and water, or an equivalent nonflammable 
solu on, as applicable.  (Since some leak test 
solu ons, including soap and water, may cause 
corrosion or stress cracking, the piping shall be 
rinsed with water a er tes ng, unless it has been 
determined that the leak test solu on is non‐
corrosive.) 
Use approved connectors to connect the unit to 
the gas line.  Purge the gas line of any debris 
before connec on to the water heater. 