Jacuzzi J-SN180F Manual De Instalación Y Funcionamiento página 35

Ocultar thumbs Ver también para J-SN180F:
Tabla de contenido
Code  Defini on 
 
19 
Electrical Grounding  
Outgoing Water 
32 
Temperature Sensor  
Heat Exchanger Outgoing 
33 
Temperature Sensor 
Air Temperature Sensor 
34 
Fault (Indoor models only) 
Outside temperature 
41 
thermistor (outdoor 
models only) 
Inlet water temperature 
51 
thermistor (RL94 only) 
Modula ng Solenoid Valve 
52 
Signal 
57 
Burner 
61 
Combus on Fan 
65 
Water Flow Control 
70 
PC Board 
71 
Solenoid Valve Circuit 
72 
Flame Sensing Device 
79 
Water Leak Detected 
Scale Build‐up in Heat 
LC # 
Exchanger (when checking 
(LC0, 
maintenance code history, 
LC1, 
"00" is subs tuted for 
LC2,...) 
"LC#")  
FF 
Maintenance Performed 
No 
Nothing happens when 
code  
water flow is ac vated.  
 
 
Remedy 
Check all components for electrical short. 
Check sensor wiring for damage. 
Measure resistance of sensor. 
Clean sensor of scale build‐up. 
Replace sensor.  
Check for restric ons in air flow around unit and vent terminal.
Check sensor wiring for damage.
Measure resistance of sensor.
licensed 
Clean sensor of scale build‐up.
professional 
Ensure fan blade is  ght on motor sha  and is in good condi on.
 
only 
Replace sensor. 
Check sensor wiring for damage. 
Measure resistance of sensor. 
Clean sensor of scale build‐up. 
Replace sensor.  
Check modula ng gas solenoid valve wiring harness for loose or damaged terminals. 
Measure resistance of valve coil. 
 
Contact a service provider. 
Ensure fan will turn freely. 
Check wiring harness to motor for damaged and/or loose connec ons. 
Measure resistance of motor winding. 
The water flow control valve has failed to close during the bath fill func on.  Immediately turn 
off the water and discon nue the bath fill func on.  Contact a licensed professional to service 
the appliance. 
Check PC board DIP switches for correct posi on.  
Check the connec on harness at the connec on on the PC board.   
licensed 
Replace PC board. 
professional 
Replace the PC Board. 
 
only 
Verify flame rod is touching flame when unit fires. 
Check all wiring to flame rod. 
Remove flame rod and check for carbon build‐up; clean with sand paper. 
Check inside burner chamber for any foreign material blocking flame at flame rod. 
Measure micro amp output of sensor circuit with flame present. 
Replace flame rod. 
Water has been detected at the bo om of the unit.  Turn off water supply.  Check all plumbing 
internally for leakage. 
LC0~LC9 indicates that there is scale build up in the heat exchanger and that the heat 
exchanger needs to be flushed to prevent damage.  Refer to the flushing instruc ons in the 
manual.  Hard water must be treated to prevent scale build up or damage to the heat 
exchanger. 
 
To operate the water heater temporarily un l the heat exchanger can be flushed, push the 
Power bu on on the temperature controller 5  mes.  Repeated LC codes will eventually lockout 
the water heater. 
Please call Jacuzzi technical department(1‐888‐835‐9320)
 
Indicates a service provider performed maintenance or corrected an issue. 
Clean inlet water supply filter. 
 
On new installa ons ensure hot and cold water lines are not reversed. 
Verify you have at least the minimum flow rate required to fire unit. 
Check for cold to hot cross over. Isolate circula ng system if present.  Turn off cold water to the 
unit, open pressure relief valve; if water con nues to flow, there is bleed over in your plumbing. 
licensed 
Verify turbine spins freely. 
professional 
Measure the resistance of the water flow control sensor. 
only 
If the display is blank and clicking is coming from the unit, disconnect the water flow servo 
motor (GY, BR, O, W, P, BL, R).  If the display comes on then replace the water flow servo 
motor. 
Jacuzzi Signature Water Heaters J‐S180/J‐S199 
 
 
 
.
35 
Tabla de contenido
loading

Tabla de contenido