11 Dismounting
11 Dismounting
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to for the entire duration of maintenance,
servicing, mounting, dismounting and repair work:
• Switch off the power source.
• Close off the compressed air supply.
• Close off the gas supply.
• Close off the coolant supply.
• Switch off the entire welding system.
• Disconnect all electrical connections.
NOTICE
• Only qualified personnel are permitted to perform work on the device or system.
• Consult the documentation for the welding components.
• Note the following instructions:
8 Putting out of operation on page EN-13.
1 Disconnect the cable assembly from the wire feeder.
2 Remove the parts to be disconnected (changeable body, bracket, CAT robot mount, torch
neck).
EN - 18
MIG/MAG ROBO welding torch
BAL.0046 • 2019-02-07