13.
FAULTS - TECHNICAL AFTER-SALES ASSISTANCE
If the appliance is not working properly or stops working, before contacting the Customer Support Centre check the following:
USER
THE EQUIPMENT
DOES NOT WORK
THE TEMPERATURE
IS NOT SUFFICIENTLY
LOW
THE COMPRESSOR
DOES NOT START
WORKING
OR WORKS FOR
VERY SHORT PERIODS
Use and maintenance manual
GOURMET ∫ EXPO WINE
CAUSE
Blown protective fuse
The master switch is open
The plug is not inserted
Electrical black-out
Evaporator(s) completely
blocked with ice
Wrong temperature setting
Equipment being struck by
currents of air or exposed to
direct or reflected sunlight
Insufficient air flow for
cooling to the condenser
No electric power supply
to the appliance
Excessively low power voltage
Temperature set too high
81
SOLUTION
First find the cause of the trip of the switch, and then replace
the new fuse.
Close the master switch.
Insert the plug.
If the black-out should be prolonged, transfer the product into
an appropriate cold storage container.
Carry out an additional defrosting cycle.
Set the appropriate temperature.
Remove any draughts and prevent any direct or reflected
sunlight.
Remove anything which could obstruct the circulation of air
through the condenser (sheets of paper, cardboard,
insufficient slots in grille, etc.).
Check if there is a power cut.
Close the various switches on the power supply line.
Check that the mains voltage of the power supply cable
corresponds to the nominal value 220V +/- 10%.
If the temperature is higher than the air temperature
in the display chamber, the compressor will not start.
Set the suited temperature if the current temperature
is not low enough.
EN
428001127000