EN
1.6
main water circuit
1
2
3
4
6
5
12
13
20
21
Sc
M
U
KEy:
M System delivery
R System return
u domestic hot water outlet
E domesti hot water inlet
S Safety valve outlet
G Gas supply
Sc condensate outlet
condensing heat exchanger
1
combustion chamber
2
Fan
3
thermal safety thermostat
4
delivery sensor
5
6
domestic hot water heat exchanger
Water pressure switch
7
pressure gauge
8
Automatic bleed valve
9
pump
10
System expansion vessel
11
diverter valve
12
Automatic by-pass
13
domestic hot water sensor
14
Gas valve
15
domestic hot water flow meter
16
domestic hot water filter
17
Boiler drain
18
System relief valve
19
System filling
20
condensate siphon outlet
21
11
9
10
8
7
18
14
16
15
19
17
G
E
R
S
Fig. 3
1.7
Sensors
the sensors installed have the following characteristics:
– dual sensor (thermal safety/output) ntc R25°c; 10kΩ β25°-
85°c: 3435
– domestic hot water sensor ntc R25°c; 10kΩ β25°-85°c: 3435
– external sensor ntc R25°c; 10kΩ β25°-85°c: 3435
Correspondence of Temperature Detected/Resistance
Examples of reading:
tR=75°c → R=1925Ω
tR=80°c → R=1669Ω.
TR
0°C
1°C
2°C
3°C
4°C
0°C 27279
26135
25044
24004
23014
10°C
17959
17245
16563
15912
15289
20°C
12090
11634
11199
10781
10382
30°C
8313
8016
7731
7458
7196
5828
5630
5440
5258
5082
40°C
50°C
4161
4026
3897
3773
3653
60°C
3021
2928
2839
2753
2669
2229
2164
2101
2040
1982
70°C
80°C
1669
1622
1577
1534
1491
1266
1232
1199
1168
1137
90°C
973
100°C
1.8
Expansion vessel
the expansion vessel installed on the boilers has the following
characteristics:
Description
total capacity
prefilling pressure
useful capacity
Maximum system content (*)
(*) conditions of:
Average maximum temperature of the system 85°c
Start temperature at system filling 10°c.
m
CaUTION
– For systems with water content exceeding the
maximum system content (as indicated in the
table) an additional expansion vessel must be
prearranged.
– the difference in height between the relief valve
and the highest point of the system cannot exceed
6 metres. If the difference is greater than 6 metres,
increase the prefilling pressure of the expansion
vessel and the system when cold by 0.1 bar for each
meter increase.
5°C
6°C
7°C
8°C
9°C
22069
21168
20309
19489
18706
14694
14126
13582
13062
12565
9999
9633
9281
8945
8622
6944
6702
6470
6247
6033
4913
4751
4595
4444
4300
3538
3426
3319
3216
3116
2589
2512
2437
2365
2296
1925
1870
1817
1766
1717
1451
1411
1373
1336
1300
1108
1079
1051
1024
998
Brava One HE
U/m
25
30
l
9,0
kpa
100
bar
1,0
l
5,0
l
124
59