Regulation Section - gefran AGy -L Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

4.3 Regulation Section

'
AGy -L
LED
Color
PWR
green
LED turns on when the voltage + 5V is present
RS 485
yellow
LED turns on when Serial interface is supplied
Connector No. of pins
XV
2
Reserved (Fans control)
XT
10
KGB-1 and/or KGB-LCD-A keypad connector
EXP-ENC-AGY optional board connection
XENC
10
(for encoder feedback)
XS
9
9-pole SUB-D connector of RS485 serial line
XKEY
5+1
QUIX-PRG key connection
XP
40
Reserved (power board connection)
XEXP
34
Reserved (expansion boards connection)
XD
10
Reserved (FW download connection)
Jumper
Default
Jumper to disconnect 0V24 (regulation section)
from ground.
S1
ON
ON = 0V24 connected to ground
OFF = 0V24 disconnected from ground
Jumper to disconnect 0V (regulation section)
from ground.
S2
ON
ON = 0V connected to ground
OFF = 0V disconnected from ground
Selection of the internal/external supply of the
RS485 serial interface
ON = Serial interface supplied from the
S5 S6
ON
regulation section
OFF = Serial interface supplied from external
source and galvanic insulation from the
regulation card
Terminating resistor for the serial interface
RS485:
S3 S4
ON
OFF = No termination resistor
ON = Termination resistor IN
Switch
Default
Switch function of EXP-ENC-AGy board
OFF = HTL output logic encoder level (+24V)
S-1
OFF
ON = TTL output logic encoder level (+5V)
OFF = HTL output logic encoder level (+24V)
S-2
OFF
ON = TTL output logic encoder level (+5V)
Function
Function
Function
63
Tabla de contenido
loading