LCD Display
C.000 Save parameters
Save parameters command
C.001 Recall param
Recall last set of saved parameters
C.002 Load default
Recall of the factory parameters.
C.020 Alarm clear
Reset of the the Alarm List register
C.040 Recall key prog
Recall of the parameters in the external key
C.041 Save pars to key
Storage of the inverter parameter on the external key
C.050 Rst mdplc prec run
Reset mdplc error at previous run
C.060 Calculate space
Off line space evaluation
C.070 Recall kbg prog
Recall of parameters from LCD keypad
C.071 Save pars to kbg
Storage of parameters into LCD keypad
C.100 Measure stator R
Motor Autotune command
This menu is not available on the keypad. The setting and the reading of the parameters here contained, can be performed exclusively via serial line or through SBI card.
H.000
Virtual digital command
H.001
Exp virtual digital command
H.010
Virtual digital state
H.011
Exp Virtual digital state
H.020
Virtual An Output 1
H.021
Virtual An Output 2
H.022
Exp Virtual An Output 1
H.030
Profidrive Control word (see Profibus instruction manual)
H.031
Profidrive Status word (see Profibus instruction manual)
H.032
Profidrive reference (see Profibus instruction manual)
H.033
Profidrive actual reference (see Profibus instruction manual)
H.034
Drive status
H.040
Progress
H.050
Drive output frequency at 32bit (LSW) (d.000)
H.051
Drive output frequency at 32bit (MSW) (d.000)
H.052
Drive reference frequency at 32bit (LSW) (d.001)
H.053
Drive reference frequency at 32bit (MSW) (d.001)
H.054
Output speed (d.000)*(P.600) at 32bit (LSW) (d.007)
H.055
Output speed (d.000)*(P600)at 32bit (MSW) (d.007)
H.056
Speed Ref (d.001)*(P.600) at 32bit (LSW) (d.008)
H.057
Speed Ref (d.001)*(P.600) at 32bit (MSW) (d.008)
H.058
Encoder freq at 32bit (LSW) (d.301)
H.059
Encoder freq at 32bit (MSW) (d.301)
H.060
Encoder speed (d.000)*(P.600) at 32bit (LSW) (d.302)
H.061
Encoder speed (d.000)*(P.600) at 32bit (MSW) (d.302)
H.062
Bitwise reading of active alarms (bit 0 to 15). Each bit is
associated to a specific alarm, according to table 9.3.1.
238
PARAMETER
DESCRIPTION
PICK LIST
LCD Selection
Description
COMMAND
(1)
No action.
(2)
Save parameters command.
(1)
No action.
(2)
Recall last set of saved
parameters.
(1)
No action.
(2)
Load default parameters.
(1)
No action.
(2)
Clear alarm register command.
(1)
No action.
(2)
Recall parameter from PRG-KEY
key.
(1)
No action.
(2)
Storage of parameters to PRG-
KEY key.
(1)
No action.
(2)
Reset mdplc error
(1)
No action.
(2)
Start
(1)
No action.
(2)
Recall pars from keypad
(1)
No action.
(2)
Store pars into keypad
(1)
No action.
(2)
Autotune command.
HIDDEN
(1)
(1)
(2)
(1)
(1)
(2)
(1)
(1)
(2)
(1)
(1)
(2)
(1)
(1)
(2)
(1)
(1)
(2)
(1)
(1)
(2)
(1)
(1)
(2)
(1)
(1)
(2)
(1)
(1)
(2)
(1)
(1)
(2)
0
0
255
0
0
255
0
0
255
0
0
255
0
-32768 32767
0
-32768 32767
0
-32768 32767
0
0
65535
0
0
65535
0
-16384 16383
1
-16384 16383
0
0
65535
0
0
100
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
31
0
- 2
2
-1
31
0
0
2
-1
AGy -L
IPA
800
801
802
803
804
805
809
809
809
810
806
1000
1001
1002
1003
1004
1005
1006
1007
1008
1040
1041
1042
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1044
1045
1060