5 5 & & 1 1 0 0 m m i i n n u u t t e e e e s s c c a a p p e e h h o o o o d d r r e e s s p p i i r r a a t t o o r r s s
i i n n s s t t r r u u c c t t i i o o n n s s
Read this manual carefully if you have or will have the responsibility for using or servicing the
product. Like any complex piece of equipment, the TransAire 5 & 10 Minute Escape Hoods from
MSA will perform as designed only if they are used and serviced according to the instructions.
Otherwise, they could fail to perform as designed, and persons who rely on this product could
sustain serious personal injury or death.
The warranties made by MSA with respect to the product are voided if the product is not ser-
viced according to the instructions in this manual. Please protect yourself and your employees
by following the instructions. Please observe the WARNINGS and CAUTIONS inside.
We encourage our customers to write or call for a demonstration of this equipment prior to use,
or for any additional information relative to use or repairs. Call 1-800-MSA-2222 during regular
working hours, or 1-800-MSA-5555 after working hours or during emergencies. See separate
insert for NIOSH approval information.
For More Information, call 1-800-MSA-2222 or Visit Our Website at www.MSAsafety.com
CRANBERRY TWP., PENNSYLVANIA, U.S.A. 16066
TAL 139 (L) Rev. 3
© MSA 2013
5 5 m m i i n n . . a a l l u u m m i i n n u u m m 1 1 0 0 0 0 0 0 8 8 2 2 9 9 2 2 . .
1 1 0 0 m m i i n n . . c c a a r r b b o o n n f f i i b b e e r r 1 1 0 0 0 0 0 0 8 8 2 2 9 9 3 3 . .
1 1 0 0 m m i i n n . . c c a a r r b b o o n n f f i i b b e e r r 1 1 0 0 0 0 8 8 3 3 3 3 2 2 7 7 . .
5 5 m m i i n n a a l l u u m m i i n n u u m m l l e e s s s s a a i i r r 1 1 0 0 0 0 6 6 7 7 7 7 3 3 9 9 . .
1 1 0 0 m m i i n n a a l l u u m m i i n n u u m m l l e e s s s s a a i i r r 1 1 0 0 0 0 6 6 6 6 7 7 4 4 0 0 . .
Prnt. Spec. 10000005389 (A) Mat. 10008901
Doc. 10000002323
p p a a r r t t n n o o . .
Tabla de contenido
loading

Resumen de contenidos para MSA TransAire 10008292

  • Página 1 Otherwise, they could fail to perform as designed, and persons who rely on this product could sustain serious personal injury or death. The warranties made by MSA with respect to the product are voided if the product is not ser- viced according to the instructions in this manual. Please protect yourself and your employees by following the instructions.
  • Página 2: Tabla De Contenido

    TransAire 5 Minute Escape Hood Respirator SPECIAL USER INSTRUCTIONS TransAire 10 Minute Escape Hood Respirator Both respirators from MSA are approved by the National Institute for Occupational Safety and Health (NIOSH) for 1. An adequate respiratory protection program must use as an escape device from hazardous atmospheres,...
  • Página 3: Unpacking

    INTRODUCTION 5 5 - - M M i i n n u u t t e e E E s s c c a a p p e e A A p p p p a a r r a a t t u u s s 1 1 0 0 - - M M i i n n u u t t e e E E s s c c a a p p e e A A p p p p a a r r a a t t u u s s S S C C B B A A Air flows from cylinder Air flows from cylinder to...
  • Página 4: Removing The Transaire Escape Hood

    INTRODUCTION 2. Pull the hook-and-loop strip and pull the pouch cover out away from the carrier. Grasp the hood from the Inspect the apparatus after it has been cleaned and pouch and listen for the sound of air rushing inside the disinfected.
  • Página 5 DESCRIPTION 10. Use a damp cloth or sponge saturated in Confidence Plus Germicidal Cleaner to clean the muffler, muffler Do not use the apparatus if any parts are damaged or cover, diffuser, hood hose, pressure regulator, cylinder missing. The apparatus is used to sustain life in haz- valve and air cylinder clean.
  • Página 6 DESCRIPTION b. Open and close the valve to be sure it works prop- 4. Place the hood into the erly. pouch on the carrier by c. Inspect the pressure gauge: first inserting the tube • The lens must not be cracked or broken. into the pouch, fol- •...
  • Página 7 Como sucede con todo equipo complejo, las capuchas de escape de 5 y 10 minutos TransAire de MSA funcionarán conforme a su diseño solamente si se usan y se mantienen de acuerdo a las instrucciones. De lo contrario, podrían no funcionar correctamente y las personas que dependen de estas podrían sufrir lesiones personales graves o la muerte.
  • Página 8: Información De Aprobación De Niosh

    Federal Regulations, CFR) Parte 1910. 134]. TransAire 2. Este respirador funcionará conforme a su diseño sola- Ambos respiradores de MSA han sido aprobados por mente si se usa de acuerdo con las instrucciones del el Instituto Estadounidense de Seguridad y Salud fabricante.
  • Página 9: Introducción

    INTRODUCCIÓN CÓMO COLOCARSE LA CAPUCHA IPVS se define como: DE ESCAPE TRANSAIRE “ ... condiciones que presentan una amenaza inme- diata para la vida o la salud o condiciones que pre- Nota: El cilindro se puede portar de tres formas: sentan una amenaza inmediata de exposición grave en el pecho, la cadera o la cintura.
  • Página 10: Cómo Quitarse La Capucha De Escape Transaire

    INTRODUCCIÓN CÓMO QUITARSE LA CAPUCHA b. Quite la correa del portacilindro del anillo en D DE ESCAPE TRANSAIRE y ajústela a su tamaño máximo. c. Colóquese la correa de hombro. Hale la correa de Para quitarse la capucha: ajuste para que el ajuste quede ceñido y cómodo. 1.
  • Página 11: Descripción

    DESCRIPCIÓN 11. Cuando las piezas estén secas, vuelva a instalar el escape, el difusor y 3. Destornille la tuerca de la tapa del escape en la la manguera y saque el capucha. Asegúrese de accesorio de la que la tapa del escape manguera fuera de la esté...
  • Página 12 DESCRIPCIÓN Instrucciones de embalaje de la capucha del aparato TransAire 1. Extienda la capucha b. Verifique para ase- plana y dóblela en gurarse de que hay tercios a lo largo. un anillo tórico en la entrada del regulador. c. Verifique para asegurarse de que hay un anillo tóri- co en la boquilla que se encuentra en el extremo de la capucha de la manguera.
  • Página 13 DESCRIPCIÓN 2. Ponga un cilindro de aire lleno en el portacilindro y amarre para cerrar la apertura alrededor del cuel- lo del cilindro. 3. Verifique para asegurarse de que hay un anillo tóri- co en la boquilla de la manguera de la capucha. 4.
  • Página 14 NOTES TAL 139 (L) Rev. 3 - 10008901...
  • Página 15 NOTES TAL 139 (L) Rev. 3 - 10008901...
  • Página 16 For More Information, call 1-800-MSA-2222 or Visit Our Website at www.MSAsafety.com CRANBERRY TWP., PENNSYLVANIA, U.S.A. 16066...