Ulm 3
English
- Mount the back panel.
Note: Make sure the knurled end of pins 4-5-6 is inserted all the way in the appropriate housings
Rif. 14.
MULTIPLEXING KIT
Ref.
Code
Description
1
02047000 Alignment pin
2
04711065 Screw TCEI M8X120 (Cylindrical head and flush hexagon)
3
04480112 Ring D 8,5x24
4
04711040 Screw TCEI M8X35 (Cylindrical head and flush hexagon)
5
04230600 Hexagonal nut M8
6
02940652 Alignment pin
16. Maintenance and cleaning
IMPORTANT! BEFORE ANY MAINTENANCE OR CLEANING OPERATIONS ARE CARRIED OUT,
CUT OFF POWER SUPPLY TO THE CABINET BY MEANS OF THE MAIN SWITCH.
Food products can deteriorate due to germs and bacteria.
Respect of the rules of hygiene is indispensable to ensure the safeguard of consumer health and
respect of the cold chain.
Cleaning of the refrigerating cabinets is distinguished as follows:
Cleaning the external parts (Daily / Weekly)
- Clean all the external parts of the cabinet weekly using neutral detergents for domestic use or soap
and water.
- Rinse with clean water and dry using a soft cloth.
- DO NOT use abrasive products and solvents that may in any way alter the surfaces of the cabinets.
- DO NOT spray water or detergent on the electric parts of the cabinet.
- DO NOT use alcohol to clean parts in metacrylate (plexiglas).
Cleaning the internal parts (Monthly)
Cleaning of the inner parts of the cabinet aims at eliminating all of the pathogenic micro-organisms so
as to thus better protect the foodstuffs contained.
Before carrying out the inner cleaning of a cabinet or of a part of one:
- Empty it completely of all the foodstuffs it contains.
- Cut off power supply to the cabinet by means of the main switch.
- Unmount all the removable parts such as display trays, various grids, etc.
- Wash with warm water and detergent containing disinfectant, then dry carefully.
- Carefully clean the bottom tray and eliminate any foreign bodies that may have fallen onto the fan
holder casing through the intake grating.
- In the case of abnormal formation of ice, please call a Qualified Refrigerator Technician.
To protect hands during this operation, wear working gloves.
Once the cleaning operations have been completed, re-mount all the removable parts (cleaned and
dried) and restore power supply. Once the internal operating temperature has been reached, the
products to be displayed can be replaced inside the cabinet..
Note:
Make sure that fans, ceiling lights, electric cables and any other electric equipment are
not wetted during cleaning.
22
05060078 00 01/06/2007