Powermate DF7500E Serie Manual Del Usuario página 12

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Connect LPG Tank
1. Remove safety plugs or caps from cylinder
valve, generator mounted regulator, and
regulator connecting hose ends.
2. With LPG tank closed, attach LPG regula-
tor connecting hose into valve. Turn plastic
coupling from the hose right (clockwise) to
tighten hose assembly onto LPG tank.
See
Figure
2-15.
Figure 2-15. Connect Hose Assembly to LPG
3. Connect opposite regulator connecting
hose end to generator at mounted LPG
primary regulator with a 3/4 in. (19mm)
wrench (not supplied). See
Figure 2-16. Connect Hose to Regulator
4. Turn LPG tank valve ON and check for
leaks by spraying soapy water to check
connections. If bubbles appear, become
larger in size, or increase in number, a
leak exists. See
NOTE: Always position cylinder so the con-
nection between the valve and regulator won't
cause sharp bends or kinks in hose.
Figure 2-17. Turn LPG Tank Valve On
10
Tank
Figure
2-16.
Figure
2-17.
NOTE: This must be corrected before using
generator. Contact your local IASD for assis-
tance.
Risk of burns. Contact with liquid contents of cylinder
will cause freeze burns to the skin. If liquid contents
contacts skin or eyes, seek immediate medical attention.
Keep out of reach of children.
NOTE: When transporting and storing, keep
cylinder secured in an upright position with
cylinder valve turned off and the outlet
plugged. Keep cylinders away from heat and
ventilated when in a vehicle.
002605
002607
002606
WARNING
CAUTION
Owner's Manual for Portable Generator
(000201)
(000128)
Tabla de contenido
loading

Este manual también es adecuado para:

Df3500e serie

Tabla de contenido