2 Safety

3 Description of the appliance

Use of tools
Unsuitable tools and/or improper use of tools may
cause damage, such as gas or water leaks.
>
Always use a suitable open-ended spanner to tighten
or loosen threaded connections.
>
Do not use pipe wrenches, extensions, etc.
2.4

Regulations

The gas fired instantaneous water heater must only be
installed by a qualified specialist tradesman
who also assumes the responsibility for installing the
unit properly and commissioning it for the first time.
The electrical installation may only be performed by a
qualified specialist tradesman.
Before the gas fired instantaneous water heater is
installed, the comments of the gas supply company and
the district chimney sweep must be obtained.
6
3
Description of the appliance
3.1

Type plate

You will find the type plate on the front, on the flow cut-
out. To see it, you must take off the housing, see 4.5.1.
The type plate contains the following information:
Symbol
Meaning
MAG
Product category
INT; MT; ES; ...
Country code
mini 11-0/0
Performance: XX in l/min; type: chimney
connection; appliance generation
I
With electronic ignition and battery
X
With flue gas sensor
atmoMAG
Series
Typ
Type of flue gassystem and combustion
air supply
B11
Gas appliance using room air with flow
cutout in flue path without fan
B11 BS
With flue gas monitoring system
INT: cat. II
Gas type code (depending on the coun-
2H3B/P
MT: cat. I
try of destination):
3B/P
...
Suitable for natural gas and liquid gas
2H
Natural gas types
G 20 – 0,002 MPa
Natural gases with permissible gas pres-
(20 mbar)
sures
3 B/P
Liquid gas types
G 30/G 31 –
Liquid gases with permissible gas pres-
0,0028 - 0,003/
sures
0,0037 MPa
(28 - 30/37 mbar)
3B/P - G30/G31 -
0,003 MPa (30 mbar)
P
Maximum heating power
nom.
P
Minimum heating power
min.
Q
Maximum thermal load
nom.
Q
Minimum thermal load
min.
pw
Maximum permissible water pressure
max.
CE 0099
Certifying authority
CE-99BP821
Product certification number
xxXXxxXXXXXX<<<<xxxx
Digits 3 and 4 are the year of produc-
xxxxxxNx
tion, 7 to 12 are the item number, and
the other digits are for production
control.
XXxx
Quality code, e.g. AC15
Table 3.1 Type plate
Installation manual atmoMAG mini 11-0/0 XI 838291_05