DFME−...−LAS
·
Wire the DFME−LAS to the controller at
connection 5 (compare Fig. 5).
Additional earthing of the DFME−LAS is
not necessary.
·
Use the original connecting cables
from Festo in accordance with the
Accessories" chapter.
1. Unscrew the cover screws and remove the
cover of the housing (A).
2. Wire the plug connector in accordance
with the following table.
3. Use the cable terminal (B) to ensure strain
relief for the cables.
4. Fasten the housing cover again without
squeezing the cables (tightening torque
of the cover screws: 0.6 Nm). The encoder
cable (10.5 mm) and motor cable (8 mm)
can be fixed with the accompanying cable
guide aJ.
Pin
1
2
3
4
1
2
3
4
Festo DFME−...−LAS 0904NH English
Cable colour
Designation
Black
W
Green
V
Red
U
n.c.
White
W/
Yellow
V/
Blue
U/
n.c.
5
Fig. 5
Fig. 6
Function
Pin allocation
String W
String V
String U
Reserved
Black plug
String W/
String V/
String U/
Reserved
Black plug
aJ
(A)
(B)
3
3
2
2
4
4
1
1
3
3
2
2
4
4
1
1