4.2 Air connection
FIGURE 7: In the case of non canalized installation, respect the distances indicated.
However, it is recommended to use the accessory to divert the output curve of the cold air, in order to avoid
the possibility of being aspirated.
WARNING: Do not use outdoor grills resulting in high losses, such as anti-insect grilles.
WARNING! A type of canalization not suitable affects product performance and significantly
increases the heating time!
4.3 Electrical connections
Description
Alimentation
WARNING: BEFORE YOU GET ACCESS TO TERMINALS, ALL SUPPLY CIRCUITS MUST BE DISCONNECTED
The protection against corrosion, given by the impressed current anode, is ensured only when the
product is connected to the mains.
Availability
Cable supplied
The earth connection of the appliance is required.
PERMANENT ELECTRICAL CONNECTION (24 h/24 h)
Cable
30
Type
Protection