TROUBLE SHOOTING:

NO VOLTAGE IN A.C. SOCKET (13.1):
IS THE PROTECTION SWITCH ON?
IS THE REQUIRED VOLTAGE SELECTED ON THE SWITCH? ⊗
ARE THE PANEL CABLES IN GOOD STATE?
IS THE CONDENSER IN GOOD CONDITIONS? ⊗⊗
IS THERE ALWAYS LACK OF VOLTAGE WHEN THE CONDENSER
HAS BEEN ENERGIZED AT THE CONNECTORS WITH A 12V BATTERY? ⊗⊗
TAKE THE GENERATOR TO THE NEAREST SERVICE CENTRE.
TROUBLE SHOOTING (MOTOR WELDING SET SECTION)
NO VOLTAGE IN A.C. SOCKET AND/OR WELDING SOCKETS (14.2):
IS THE PROTECTION SWITCH ACTIVATED?
IS THE SWITCHBOARD WIRING IN GOOD CONDITIONS?
ARE THE CONDENSERS IN GOOD CONDITIONS?
IS THE RECTIFIER IN SHORT CIRCUIT?
TAKE THE GENERATOR TO THE NEAREST SERVICE CENTRE
THE ENGINE DOES NOT START (15.1):
IS THERE ANY FUEL IN THE TANK?
IS THERE AIR IN THE FEEDING CIRCUIT? ⊗⊗
IS THE SPARK PLUG CONNECTED? ⊗⊗⊗
TAKE THE GENERATOR TO THE NEAREST SERVICE CENTRE
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
IS THE FUEL TANK TAP OPEN? ⊗
YES
YES
IS THE CHOKE ON? ⊗⊗⊗
YES
IS THERE OIL IN THE ENGINE?
YES
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
17
ACTIVATE
ACTIVER
REPAIR
REPLACE
GENERATOR OK
⊗ ONLY WHEN FORESEEN
⊗⊗ SINGLE-PHASE GENERATORS
ACTIVATE
RESTORE
REPLACE
MOTOR WELDING SET OK
FILL TANK
OPEN
ELIMINATE
ACTION
FILL UP
CONNECT
⊗ ONLY WHEN FORESEEN
⊗⊗ ONLY FOR DIESEL ENGINE
⊗⊗⊗ ONLY FOR EXPLOSION ENGINE