PARAMETER
VALUE
I.ADI
NO
SI
RICH
NO
SI
T.ADD
0.5"-1'
NO
FINE
NO
SI
SUBMENU
DESCRIPTION
ADI device enable
ADI interface disabled
ADI interface enabled
Reclosing at startup
Function disabled
When the power supply is activated the unit
set for closing: the first START command starts
the motor closing. If the automatic closing is
activated (CH.AU), the count of pause time
starts and closing is activated
Extra travel
If in some cases the gate does not reach the
position needed to activate the limit switch,
you can set an additional time by configuring
the parameter
not activated the gate continues its movement
up to the end of the set time
The gate ends its travel even if the limit
switches have not been activated
Exit the programming menu
Do not exit the programming menu
Exits the programming menu by storing the
parameters set
: if the limit switches is
T.ADD
- 86 -
DEFAULT
CHAPTER
MEMO
21
NO
SI
1.0"
NO