23 - OPERATION DEFECTS
This paragraph shows some possible operation defects, along with their cause and applicable remedy.
DISPLAYING
MAINS led off
OVERLOAD led on
Extended pre-flashing time of the BLINKER
The display shows
ERR1
The display shows
ERR3
The display shows
ERR4
The display shows
ERR5
The display shows
ERR6
The display shows
ERR7
The display shows
ERR9
The display shows
ERR10
The display shows
HALT
DESCRIPTION
Faulty power supply of logics
24V power supply to accessories overload
When a start command is given the blinker
immediately turns up, but the gate does not
open immediately: the count of cycles set
for Service has expired
Software error
The functionality test of the photocells failed 1. Make sure there are no obstructions
Limit switch error
The function test of safety ribbons failed
Amperometric sensor error
Encoder error
Access to the programming menu locked by
CL1+
The function test of the safety devices
connected to the interface ADI failed
Emergency stop enabled
- 87 -
SOLUTION
Check fuse F1
1. Remove the terminal block H1-H8: the
OVERLOAD LED turns off
2. Solve the problem causing overloading
(terminals E1-E3)
3. Re-install the terminal board and make
sure the LED does not turn on again
Enter the menu of the counters and reset
the Service parameter
Send the unit to the service department
between the photocells
2. Check that the photocells enabled by
menu are actually installed and working
3. If type 2 photocells are used, make sure
that the menu item
FOT2
CFCH
4. Check out the preceding conditions, if
the error persists, increase the time of the
test (parameter
)
FT.TE
Check that the limit switches are properly
connected and that the limit switches are
activated at the movement of the gate
1. Make sure that the safety ribbons
enabled by menu are actually installed
and working
2. Ensure that the control unit of the
safety ribbons is properly connected and
working
If the error persists send the unit to the
Service department
Check the connection of the encoder
Insert the CL1+ module with which the
programming was locked into the ADI
connector: the unit will automatically enter
the programming menu
PRG
Verify that the ADI module is connected.
Check that the safety devices connected to
the ADI interface are properly connected
and working
Turn off the STOP button between terminals
T1 and T2. If you have not installed a switch
the two terminals must be bridged
is set to