16 - CONTROL MODE FROM TERMINAL
BOARD
To control the gate through external devices you need have to
connect devices with normally open contact between terminals
S1-S4, S2-S4 or S3-S4 and set for each the desired function via
the parameters
,
ING1
ING2
The functions available are:
• Start (
value to be set)
START
This function corresponds to a generic activation command and
controls the following operations:
- When the gate is closed, an opening cycle starts
- When the gate is opening depends on the setting of parameter
:
ST.AP
: command not active
NO
: the gate closes immediately
CHIU
: the gate stops (if the automatic closing mode is on the
PAUS
pause time counting starts)
- When the gate is open and the pause the counting is not
active, the closing starts
- When the gate is open and the pause time counting is active,
depends on the menu
ST.PA
: command not active
NO
: closing starts
CHIU
: reset the pause time counting
PAUS
- When the gate is closing depends on the menu
: the gate re-opens
APRE
: the gate will stop and the cycle is considered finished
STOP
- When the gate is stopped due to a stop command or the
detection of an obstacle, a command Start restarts the gate in
the same direction as it was before being stopped.
If the parameter
is set to
STOP
but in the opposite direction.
- When the gate began a partial opening cycle commands a
total opening
• Partial start (
value to be set)
ST.PE
This function corresponds to a partial opening command and
controls the following operations:
- When the gate is closed, a partial opening cycle starts; the gate
opens only for the percentage of travel set in the parameter
P.APP
Once you start the cycle, the functions are those described the
START command.
- When the gate began a normal opening cycle this command
has no effect.
and
.
ING3
:
:
ST.CH
the gate again moves,
INVE
• Stop (
value to be set)
STOP
This function corresponds to a stop command: it is the only
case in which the connected device must work with normally
closed contact; it can be used to stop the gate and hold it in a
locked position.
The operation of the STOP command depends on the value set for
the parameter STOP:
-
: the gate stops in its current position and as long as the
PROS
contact is open no command is effective.
Once the contact is closed again, any start command restarts
the gate that follows its previous direction.
-
: the gate stops in its current position and as long as the
INVE
contact is open no command is effective.
Once the contact is closed again, any start command restarts
the gate in the opposite direction.
-
: the gate stops any movement and opens completely. If
APRE
an active safety device prevents the opening, the gate does not
move until the device involved is deactivated, then it opens.
So the gate remains locked in the open position until the STOP
contact closes again.
-
: the gate does not stop the movement immediately, but
CHIU
when it stops it closes.
If a safety device causes its re-opening, the operation is carried
out, then again closing is commanded.
When the gate is closed, it remains locked in this position until
the STOP contact is closed again.
• Always opens (
APRE
Always controls the opening, regardless of the position of the
gate, if the gate is already open, it is ineffective.
NOTE: This command is not available for the input
• Always closes (
CHIU
Always control the closing: if the gate is already closed it is
ineffective.
NOTE: This command is not available for the input ING3.
• Force dead man mode (
This command is available only on the input ING3: when the
contact is closed the unit is operating in dead man mode.
- 76 -
value to be set)
ING3
value to be set)
value to be set)
PRES
.