Style 2 - Connection
to Water Line
1. Unplug refrigerator or disconnect
power.
2. Remove and discard the black nylon plug from the gray water
tube on the rear of the refrigerator.
3. If the gray water tube supplied with the refrigerator is not long
enough, a 1/4"x 1/4"(6.35 mm x 6.35 mm) coupling is needed
in order to connect the water tubing to an existing household
water line. Thread the provided nut onto the coupling on the
end of the copper tubing.
NOTE: Tighten the nut by hand. Then tighten it with a wrench
two more turns. Do not overtighten.
A
B
C
D
E
F
G
A. Refrigerator
water tubing
E. Ferrule (purchased)
B. Nut (provided)
F Nut (purchased)
C. Bulb
G. Household
water fine
D. Coupling (provided)
4. Turn shutoff valve ON.
5. Check for leaks. Tighten any nuts or connections
(including
connections
at the valve) that leak.
Style 3 - Connection
to Shutoff Valve
1. Unplug refrigerator or disconnect
power.
2. Remove and discard the black nylon plug from the gray water
tube on the rear of the refrigerator.
3. Thread the provided nut onto the water valve as shown.
NOTE: Tighten the nut by hand. Then tighten it with a wrench
two more turns. Do not overtighten.
A
I/
II
B
Complete the Installation
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
1. Plug into a grounded 3 prong outlet.
2. Flush the water system. See "Prepare the Water System."
NOTE: It may take up to 24 hours for your ice maker to begin
producing ice.
Please read before using the water system.
Immediately after installation, follow the steps below to make
sure that the water system is properly cleaned.
1. Open the freezer door and turn off the ice maker. For Style 1,
lift up the wire shutoff arm as shown. For Style 2, move the
switch to the OFF (right) setting as shown. The On/Off switch
is located on the top right side of the freezer compartment.
Style 1
Style 2
4=
5.
A. Bulb
B. Nut (provided)
Turn shutoff valve ON.
Check for leaks. Tighten any nuts or connections
(including
connections
at the valve) that leak.
NOTE: If your model has a base grille filter system, make sure the
base grille filter is properly installed and the cartridge cap handle
is in the horizontal position.
Do not use with water that is microbiologically
unsafe or
of unknown quality without adequate disinfection before
or after the system. Systems certified for cyst reduction
may be used on disinfected waters that may contain
filterable cysts.
9