4.4.4) Activation of the Closure torque reduction (RDC)
The torque reduction is a programmable function that prevents excessive tension on the fabric by reducing the pulling torque by approxi-
mately 50% just before the awning is fully retracted against the box.
Table "A10"
Programming the torque reduction (RDC)
Press and hold down button n of a previously memorized transmitter until you hear a
1.
beep (after about 5 seconds)
Release and press again button n for another 5 seconds until 4 rapid beeps are heard
2.
Press button n until 3 beeps indicate that the RDC function has been activated
3.
4.4.5) Programming of the "FRT" function
After having programmed positions "0" and "1", position "2" can be programmed that activates the retraction function FRT of the fabric.
Follow the indications in table "A11" to program position "2".
Table "A11"
Programming position "2"
Press and hold down button n of a previously memorized transmitter until you hear a
1.
beep (after about 5 seconds)
Press and hold buttons n t for another 5 seconds until 2 rapid beeps are heard.
2.
At this point the awning automatically moves to the position of the lower limit switch
(position "1")
Use buttons t and s within 5 seconds to position the awning in the desired
3.
retraction position
Confirm the position with button n of the transmitter within 5 seconds until 3 beeps are
4.
heard. Afterwards the awning will move to the lower programmed limit switch position
(position "1")
Note: if the programming described in point 4 is not confirmed the modifications are aborted and the previous programming is maintained.
If after having programmed this function you wish to eliminate it, the procedure in table A15 must be followed, omitting step 3 which would
modify position "1".
When position "2" is programmed, the electronic control unit automatically calculates the difference between positions "2" and "1", so that
each time a lower command is given, the awning lowers to the greater of the two positions and then retrieves the fabric until arriving to the
lesser of the two positions.
4.4.6) Programming of the "FTC" function.
After having programmed positions "0" and "1", position "S" can be programmed that activates the "FTC" function for the automation of awnings
with an automatic hooking mechanism. Until the mechanism is working correctly, position "1" must be programmed a few centimetres after the
hooking point so that hooking occurs when retracting from point "1", and position "S" is programmed a few centimetres after the release point
so that the ascent from point "S" is performed freely.
Follow the procedure indicated in table "A12" to program position "S":
Table "A12"
Programming the release position "S"
Press and hold down button n of a previously memorized transmitter until you hear a
1.
beep (after about 5 seconds)
Press and hold buttons n t for another 5 seconds until 2 rapid beeps are heard.
2.
At this point the awning automatically moves to position "1"
Use buttons t and s within 5 seconds to position the awning in the release
3.
position "S" (below position "1")
Confirm the position by pressing buttons t and s of the transmitter together within
4.
5 seconds until 3 beeps are heard. At this point the awning will automatically move
to position "0"
Note: if the programming described in point 4 is not confirmed the modifications are aborted and the previous programming is maintained.
If after having programmed this function you wish to eliminate it, the procedure in table "A13" must be followed, omitting step 3 which would
modify position "1".
7
Example
5s
5s
Example
5s
5s
Example
5s
5s