Troubleshooting - hilmor 1950536 Instrucciones De Operacion Y Mantenimiento

Máquina de recuperación de refrigerante cd sin escobillas de peso ligero
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

ISSUE
Machine will not
start
Machine
hammering or
jumping
Machine stopped
recovery
Slow Recovery
No display on LCD
If these procedures do not correct the issue, contact your nearest
hilmor® Distributor or call hilmor® Technical Support at 1-800-995-2222 .
CAUSE
No power
High pressure shut
Circuit breaker
popped
Motor fault (M LED
indicator is lit)
Over voltage
Compressor
slugging
Low pressure shut
High pressure shut
Over current circuit
breaker tripped
Flow restriction
High recovery
cylinder pressure
No power to LCD
ROOT CAUSE
SOLUTION
No connection/Bad
Plug in power cord or use alternate
outlet
outlet
Turn on the power switch on side of unit
position
and observe the green light
Full cylinder, closed
valve, clogged hose
below. At this time the "HP" LED will
flash
Over current
Reset circuit breaker on front end panel
High motor
Allow time for your machine to cool
temperature
down. Call technical support if the issue
persists
Inadequate power
Use shortest possible 16 gauge (AWG)
cord, low voltage at
source
In excess of 132V
Find power source with proper
from power source
Excessive liquid
Throttle valve down by adjusting the
refrigerant in the
knob when recovering liquid
compressor
No more refrigerant
Recovery is complete
in the system
Inlet line hose is
Clean out the filter, check for blockage
clogged
Inlet valve, hilmor®
Open appropriate valves
Recovery Machine,
or manifold valve is
closed
Full recovery
Check the weight, and replace with
cylinder
empty cylinder
High tank
Cool recovery cylinder
temperature
Valve is closed
Ensure all necessary valves are open
Clogged outlet line
Clear the clog
hose
Motor overload,
high temp
Closed or partially
Ensure valves are all the way open
closed valve
Clogged hose
Ensure hoses are clear of debris
Clogged filter
Clean or replace inlet filter screen
screen
High temperature
Cool the tank
Full tank
Swap to empty tank
Flip switch to power the machine
position
ENGLISH
17
17
Tabla de contenido

Solución de problemas

loading

Tabla de contenido