Page 18
ENGLISH
3.
Keep the motor covered and dry. Do not cover
the pump with plastic, because this will create
condensation that will damage the pump.
NOTE Zodiac Pool Systems, Inc. recommends
having a qualified service technician or electrician
properly disconnect the electrical wiring at
the switch or junction box. Once the power is
removed, loosen the two (2) unions and store the
pump indoors. For safety, and to prevent entry of
contaminants, reinstall all conduit and terminal box
covers.
4.
When the system is reopened for operation,
have a qualified technician or electrician make
sure all piping, valves, wiring and equipment
are in accordance with the manufacturer's
recommendations. Pay close attention to the filter
and electrical connections. Inspect all suction
outlet fittings and covers and ensure they are not
broken and are properly installed and secured.
5.
The pump must be primed prior to starting. Refer
to Section 4.1, Start-up.
6.
The SVRS unit must be tested for proper
operation. See section 3.7 for instructions.
Section 6. Troubleshooting and
Repair
To order or purchase parts for Jandy pumps, contact
your nearest Jandy dealer. If the Jandy dealer cannot
supply you with what you need, contact Zodiac
Technical Support at 1.800.822.7933, or send an e-mail
6.1
Service Technician Maintenance
WARNING
This pump must be serviced by a professional
service technician qualified in pool/spa installation.
The following procedures must be followed exactly.
Improper installation and/or operation can create
dangerous electrical hazards, which can cause
high voltages to run through the electrical system.
This can cause property damage, serious personal
injury, and/or death. Improper installation and/or
operation will void the warranty.
WARNING
Before servicing the pump, switch off the circuit
breakers at the power source. Severe personal
injury or death may occur if the pump starts while
your hand is inside the pump.
Jandy
Pro Series ePump
+ SVRS
®
™
Blocked Impeller
1.
Turn off the pump. Switch off the circuit breaker to
the pump motor.
2.
Remove the lid and filter basket.
3.
Look inside the pump for debris. Remove any
debris found inside.
4.
Replace the filter basket and lid.
5.
Switch on the circuit breaker to the pump motor.
6.
Turn on the pump, and see if the problem is
solved.
7.
If the impeller is still blocked with debris and it
is not possible to remove the debris using Steps 2
through 4, the pump will need to be disassembled
in order to access the inlet and outlet of the
impeller.
|
Installation and Operation Manual